Parameters
List of parameters
1-108
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the number of Drive Data Sets (DDS).
Description:
Using the parameter, each Drive Data Set (= index) is assigned the associated Motor Data Set (MDS).
The parameter value therefore corresponds to the number of the assigned motor data set.
Description:
Using the parameter, each Drive Data Set (= index) is assigned the associated Encoder Data Set (EDS) for
encoder 1.
The parameter value therefore corresponds to the number of the assigned encoder data set.
Example:
Encoder data set 0 should be assigned to encoder 1 in drive data set 2.
--> p0187[2] = 0
Note:
A value of 99 means that no encoder has been assigned to this drive data set (not configured).
Description:
Using the parameter, each Drive Data Set (= index) is assigned the associated Encoder Data Set (EDS) for
encoder 2.
The parameter value therefore corresponds to the number of the assigned encoder data set.
Note:
A value of 99 means that no encoder has been assigned to this drive data set (not configured).
p0180
Number of Drive Data Sets (DDS) / DDS count
SERVO, TM41, VEC-
TOR
Can be changed:
C1(3)
Calculated:
-
Access level:
2
Data type:
Unsigned8
Dynamic index:
-
Func. diagram:
8565
P-Group:
Data sets
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
1 32
1
p0186[0...n]
Motor Data Sets (MDS) number / MDS number
SERVO, VECTOR
Can be changed:
C1(4)
Calculated:
-
Access level:
3
Data type:
Unsigned8
Dynamic index:
DDS, p0180
Func. diagram:
8575
P-Group:
Data sets
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 15
0
p0187[0...n]
Encoder 1 encoder data set number / Enc 1 EDS number
SERVO, VECTOR
Can be changed:
C1(4)
Calculated:
-
Access level:
3
Data type:
Unsigned8
Dynamic index:
DDS, p0180
Func. diagram:
1580, 8570
P-Group:
Data sets
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 99
99
p0188[0...n]
Encoder 2 encoder data set number / Enc 2 EDS number
SERVO, VECTOR
Can be changed:
C1(4)
Calculated:
-
Access level:
3
Data type:
Unsigned8
Dynamic index:
DDS, p0180
Func. diagram:
1580, 8570
P-Group:
Data sets
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 99
99
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...