Parameters
List of parameters
1-704
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the level of the excitation frequency for identification of the total DC link capacitance. The amplitude is indi-
cated as a percentage of the DC voltage setpoint (Vdc = p0210 * p3510).
Dependency:
Refer to: p3410, r3412, p3422
Description:
Sets the level of the excitation frequency for identification of the total DC link capacitance.
Dependency:
Refer to: p3410, r3412, p3422
Description:
Sets the total effective inductance for the closed-loop current control from the sum of the line supply inductance and
inductance of the commutating reactor.
This parameter is preset to the sum of p0223 and p0225.
Dependency:
Refer to: p0223, p0225, p3410, p3425, p3614, p3622
Note:
The controller setting is derived from this value and p3425.
The value can be automatically determined using the identification run (p3410).
For a parallel circuit, the value corresponds to the inductance of a power unit.
For the inductance value of the commutating reactor, p3421 - p3424 applies.
Description:
Sets the DC link capacitance for the closed-loop voltage control.
This value is preset to p0227.
Dependency:
Refer to: p0227, p3410, p3425
Note:
The controller setting is derived from this value and p3425. A suitable value can be automatically determined using
the identification run (p3410).
p3416
Infeed excitation amplitude C identification / INF exc_amp C_Id
A_INF, S_INF
Can be changed:
T
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.10 [%]
20.00 [%]
2.00 [%]
p3417
Infeed excitation frequency C identification / INF f_exc C_ID
A_INF, S_INF
Can be changed:
T
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
10.00 [Hz]
200.00 [Hz]
50.00 [Hz]
p3421
Infeed inductance / INF Inductance
A_INF, S_INF
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.001 [mH]
2000.000 [mH]
1.000 [mH]
p3422
Infeed DC link capacitance / INF C_DCL
A_INF, S_INF
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.20 [mF]
2000.00 [mF]
2.00 [mF]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...