List of parameters
Parameters
1-733
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
The binector output uses a 1 signal to indicate an overtemperature condition at the connected temperature sensor
of the braking resistor.
Description:
The binector output uses a 1 signal to indicate that the highest permissible overtemperature at the connected tem-
perature sensor has been reached and has caused a trip (shutdown).
Dependency:
Refer to: F06908
Description:
The binector output uses a 1 signal to indicate that there is a Vce fault in the Digital Braking Module.
Dependency:
Refer to: F06909
Description:
Sets the configuration for APC (Advanced Positioning Control).
Note:
Re bit 0:
For a 1 signal, the acceleration filter output is added to the speed setpoint.
For a 0 signal, the value 0 is added. This must be used to evaluate the filter frequency characteristics.
Re bit 8:
For bit 0 = 1 and activated pulse de-coupling (bit 8 = 1), the speed of the direct measuring system (p3701) selected
for APC is used as the actual value for the closed-loop speed control.
r3687
BO: Digital Braking Module pre-alarm overtemperature / Dig BM temp alarm
B_INF
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r3688
BO: Digital Braking Module fault overtemperature / Dig BM temp fault
B_INF
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r3689
BO: Digital Braking Module Vce fault / Dig BM Uce fault
B_INF
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
p3700
APC configuration / APC config
SERVO (APC)
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
7012
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- -
0000
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Activating APC
Yes
No
-
08
Activating pulse de-coupling
Yes
No
-
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...