FlexRay Communication Controller (FlexRAY)
PXN20 Microcontroller Reference Manual, Rev. 1
Freescale Semiconductor
26-105
The amount of message data read from the FlexRay memory and transferred to the FlexRay bus is
determined by the following three items
1. the message buffer segment that the message buffer is assigned to, as defined by the
Buffer Segment Size and Utilization Register (MBSSUTR)
.
2. the message buffer data field size, as defined by the related field of the
3. the value of the PLDLEN field in the message buffer header field, as described in
Section 26.6.5.2.1, Frame Header Description.
If a message buffer is assigned to message buffer segment 1, and PLDLEN > MBSEG1DS, then
2 * MBSEG1DS bytes will be read from the message buffer data field and zero padding is used for the
remaining bytes for the FlexRay bus transfer. If PLDLEN < MBSEG1DS, the controller reads and
transfers 2*PLDLEN bytes. The same holds for segment 2 and MBSEG2DS.
26.6.6.2.6
Null Frame Transmission
A static slot with slot number S is assigned to the controller for channel A, if at least one transmit message
buffer is configured with the MBFIDR
n
[FID] set to S and MBCCFR
n
[CHA] set to 1. A Null Frame is
transmitted in the static slot S on channel A, if this slot is assigned to the controller for channel A, and all
transmit message buffers with MBFIDR
n
[FID] = S and MBCCFR
n
[CHA] = 1 are either not committed
(MBCCSR
n
[CMT] = 0), or locked by the application (MBCCSR
n
[LCKS] = 1), or the cycle counter filter
is enabled and does not match.
Additionally, the application can clear the commit bit of a message buffer that is in the CCMa state, which
is called
uncommit
or
transmit abort
. This message buffer will be used for null frame transmission.
As a result of the message buffer search described in
Section 26.6.7, Individual Message Buffer Search,
the controller triggers the slot assigned transition SA for as many as two transmit message buffers if at least
one of the conditions mentioned above is fulfilled for these message buffers. The transition SA changes
the message buffer states from either Idle to CCSa or from HLck to HLckCCSa. In each case, these
message buffers will be used for null frame transmission in the next slot. A message buffer timing and state
change diagram for null frame transmission from Idle state is given in
.
Figure 26-123. Null Frame Transmission from Idle state
A message buffer timing and state change diagram for null frame transmission from HLck state is given
in
search[s+1]
MT st
art
MT s
tar
t
SA
slot s
STS
SSS
CCSa CCNf
slot s+1
Idle
MT star
t
Idle
slot s+2
slot start
slot start
slot start
null frame transmit
Summary of Contents for PXN2020
Page 1: ...PXN20 Microcontroller Reference Manual Devices Supported PXN2020 PXN2120 PXN20RM Rev 1 06 2011...
Page 42: ...PXN20 Microcontroller Reference Manual Rev 1 lxiv Freescale Semiconductor...
Page 64: ...Introduction PXN20 Microcontroller Reference Manual Rev 1 1 22 Freescale Semiconductor...
Page 112: ...Signal Description PXN20 Microcontroller Reference Manual Rev 1 3 44 Freescale Semiconductor...
Page 118: ...Resets PXN20 Microcontroller Reference Manual Rev 1 4 6 Freescale Semiconductor...
Page 372: ...e200z6 Core Z6 PXN20 Microcontroller Reference Manual Rev 1 13 8 Freescale Semiconductor...
Page 412: ...e200z0 Core Z0 PXN20 Microcontroller Reference Manual Rev 1 14 14 Freescale Semiconductor...
Page 821: ...Media Local Bus MLB PXN20 Microcontroller Reference Manual Rev 1 Freescale Semiconductor 27 49...
Page 822: ...Media Local Bus MLB PXN20 Microcontroller Reference Manual Rev 1 27 50 Freescale Semiconductor...
Page 1376: ...Memory Map PXN20 Microcontroller Reference Manual Rev 1 A 118 Freescale Semiconductor...