Nexus Development Interface (NDI)
PXN20 Microcontroller Reference Manual, Rev. 1
36-90
Freescale Semiconductor
Program Trace Synchronization Messages
A program trace direct/indirect branch with sync message is messaged via the auxiliary port (provided
program trace is enabled) for the following conditions (see
):
•
Initial program trace message upon the first direct/indirect branch after exit from system reset or
whenever program trace is enabled
•
Upon direct/indirect branch after returning from a CPU low power state
•
Upon direct/indirect branch after returning from debug mode
•
Upon direct/indirect branch after occurrence of queue overrun (can be caused by any trace
message), provided program trace is enabled
•
Upon direct/indirect branch after the periodic program trace counter has expired indicating 255
without-sync
program trace messages have occurred since the last
with-sync
message occurred
•
Upon direct/indirect branch after assertion of the event in (EVTI) pin if the EIC bits within the DC1
register have enabled this feature
•
Upon direct/indirect branch after the sequential instruction counter has expired indicating 255
instructions have occurred between branches
•
Upon direct/indirect branch after a BTM message was lost due to an attempted access to a secure
memory location.
•
Upon direct/indirect branch after a BTM message was lost due to a collision entering the FIFO
between the BTM message and either a watchpoint message or an ownership trace message
If the module is enabled at reset, a EVTI assertion initiates a program trace direct/indirect branch
with sync message (if program trace is enabled) upon the first direct/indirect branch. The format for
program trace direct/indirect branch with sync messages is as follows:
Figure 36-69. Direct/Indirect Branch with Sync Message Format
The formats for program trace direct/indirect branch with sync. messages and indirect branch history with
sync. messages are as follows
:
Figure 36-70. Indirect Branch History with Sync. Message Format
Exception conditions that result in program trace synchronization are summarized in
.
MSB
LSB
2
3
4
F-ADDR
I-CNT
SRC
4 bits
1
TCODE (001011 or 001100)
1–8 bits
1–32 bits
6 bits
Max length = 50 bits; Min length = 12 bits
HIST
MSB
LSB
2
3
4
F-ADDR
I-CNT
SRC
5
4 bits
1
TCODE (011101)
1–8 bits
1–32 bits
1–32 bits
6 bits
Max length = 82 bits; Min length = 13 bits
Summary of Contents for PXN2020
Page 1: ...PXN20 Microcontroller Reference Manual Devices Supported PXN2020 PXN2120 PXN20RM Rev 1 06 2011...
Page 42: ...PXN20 Microcontroller Reference Manual Rev 1 lxiv Freescale Semiconductor...
Page 64: ...Introduction PXN20 Microcontroller Reference Manual Rev 1 1 22 Freescale Semiconductor...
Page 112: ...Signal Description PXN20 Microcontroller Reference Manual Rev 1 3 44 Freescale Semiconductor...
Page 118: ...Resets PXN20 Microcontroller Reference Manual Rev 1 4 6 Freescale Semiconductor...
Page 372: ...e200z6 Core Z6 PXN20 Microcontroller Reference Manual Rev 1 13 8 Freescale Semiconductor...
Page 412: ...e200z0 Core Z0 PXN20 Microcontroller Reference Manual Rev 1 14 14 Freescale Semiconductor...
Page 821: ...Media Local Bus MLB PXN20 Microcontroller Reference Manual Rev 1 Freescale Semiconductor 27 49...
Page 822: ...Media Local Bus MLB PXN20 Microcontroller Reference Manual Rev 1 27 50 Freescale Semiconductor...
Page 1376: ...Memory Map PXN20 Microcontroller Reference Manual Rev 1 A 118 Freescale Semiconductor...