Frequency Modulated Phase-Locked Loop (FMPLL)
PXN20 Microcontroller Reference Manual, Rev. 1
7-8
Freescale Semiconductor
Offset: FMPLL_BAS 0x000C
Access: User read/write
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
R
0
0
0
0
0
0
0
0
LOCEN LOLRE LOCRE
LOL
IRQ
LOC
IRQ
0
ERATE
W
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
R
0
0
0
0
0
EDEPTH
0
0
ERFD
W
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
Figure 7-4. FMPLL Enhanced Synthesizer Control Register 2 (ESYNCR2)
Table 7-7. ESYNCR2 Field Descriptions
Field
Description
LOCEN
Loss-of-Clock Enable. The LOCEN bit determines whether the loss-of-clock function is operational along with
backup clock modes, and interrupt and reset functions. See
Section 7.4.3.2, Loss-of-Clock Detection,
for
more information.
In PLL Off mode, this bit has no effect.
LOCEN does not affect the loss-of-lock circuitry.
0 Loss-of-clock disabled.
1 Loss-of-clock enabled.
LOLRE
Loss-of-Lock Reset Enable. The LOLRE bit determines how the integration module handles a loss-of-lock
indication. See
Section 7.4.3.1, PLL Lock Detection,
for more information.
When operating in normal PLL mode, the PLL must be locked before setting the LOLRE bit. Otherwise reset
is immediately asserted.
The LOLRE bit has no effect in PLL Off mode.
0 Assert reset on loss of lock is disabled.
1 Assert reset on loss of lock.
LOCRE
Loss-of-Clock Reset Enable. The LOCRE bit determines how the integration module handles a loss-of-clock
condition when LOCEN is equal to 1. LOCRE has no effect when LOCEN is equal to 0.
If the LOCF bit in the SYNSR indicates a loss-of-clock condition, setting the LOCRE bit causes an immediate
reset.
The LOCRE bit has no effect in PLL Off mode.
0 Assert reset on loss of clock is disabled.
1 Assert reset on loss of clock.
LOLIRQ
Loss-of-Lock Interrupt Request. The LOLIRQ bit determines how the integration module handles a
loss-of-lock indication. See
Section 7.6.1, Loss-of-Lock Interrupt Request,
for more information.
When operating in normal mode, the PLL must be locked before setting the LOLIRQ bit. Otherwise an
interrupt is immediately requested.
The LOLIRQ bit has no effect in PLL Off mode.
0 Request interrupt is disabled.
1 Request interrupt.
LOCIRQ
Loss- of-Clock Interrupt Request. The LOCIRQ bit determines how the integration module handles a loss-
of-clock condition when LOCEN = 1. LOCIRQ has no effect when LOCEN = 0.
If the LOCF bit in the SYNSR indicates a loss-of-clock condition, setting (or having previously set) the
LOCIRQ bit causes an interrupt request.
The LOCIRQ bit has no effect in PLL Off mode.
0 Request interrupt on loss of clock is disabled.
1 Request interrupt on loss of clock.
Summary of Contents for PXN2020
Page 1: ...PXN20 Microcontroller Reference Manual Devices Supported PXN2020 PXN2120 PXN20RM Rev 1 06 2011...
Page 42: ...PXN20 Microcontroller Reference Manual Rev 1 lxiv Freescale Semiconductor...
Page 64: ...Introduction PXN20 Microcontroller Reference Manual Rev 1 1 22 Freescale Semiconductor...
Page 112: ...Signal Description PXN20 Microcontroller Reference Manual Rev 1 3 44 Freescale Semiconductor...
Page 118: ...Resets PXN20 Microcontroller Reference Manual Rev 1 4 6 Freescale Semiconductor...
Page 372: ...e200z6 Core Z6 PXN20 Microcontroller Reference Manual Rev 1 13 8 Freescale Semiconductor...
Page 412: ...e200z0 Core Z0 PXN20 Microcontroller Reference Manual Rev 1 14 14 Freescale Semiconductor...
Page 821: ...Media Local Bus MLB PXN20 Microcontroller Reference Manual Rev 1 Freescale Semiconductor 27 49...
Page 822: ...Media Local Bus MLB PXN20 Microcontroller Reference Manual Rev 1 27 50 Freescale Semiconductor...
Page 1376: ...Memory Map PXN20 Microcontroller Reference Manual Rev 1 A 118 Freescale Semiconductor...