SOURce<Ch>:POWer<PhyPt>:SWEepend:SDELay
<SettlingDelay>
If sweep end mode REDuce or KEEP is active (see
) this defines the settling delay at subsequent sweep starts, i.e. the
time between power reset and sweep start when a new sweep is requested.
This is a global setting.
Suffix:
<Ch>
.
Channel number. This suffix is ignored; the setting is valid for all
channels.
<PhyPt>
Physical port number. This suffix is ignored; the setting is valid
for all ports.
Parameters:
<SettlingDelay>
Settling delay
Default unit: s
Manual operation:
See
"Settling Delay / Reset Delay "
10.5.2.15
STATus Commands
The
STATus:...
commands control the status reporting system. Status registers are
not reset by *RST; use *CLS for this purpose.
......................................................................................894
STATus:QUEStionable:INTegrity[:EVENt]?
........................................................................894
STATus:QUEStionable:INTegrity:HARDware[:EVENt]?
.......................................................894
STATus:QUEStionable:LIMit<Lev>[:EVENt]?
.....................................................................894
STATus:QUEStionable:CONDition?
..................................................................................894
STATus:QUEStionable:INTegrity:CONDition?
....................................................................894
STATus:QUEStionable:INTegrity:HARDware:CONDition?
...................................................894
STATus:QUEStionable:LIMit<Lev>:CONDition?
.................................................................894
....................................................................................... 895
STATus:QUEStionable:INTegrity:ENABle
..........................................................................895
STATus:QUEStionable:INTegrity:HARDware:ENABle
.........................................................895
STATus:QUEStionable:LIMit<Lev>:ENABle
.......................................................................895
STATus:QUEStionable:NTRansition
................................................................................. 895
STATus:QUEStionable:INTegrity:NTRansition
................................................................... 895
STATus:QUEStionable:INTegrity:HARDware:NTRansition
.................................................. 895
STATus:QUEStionable:LIMit<Lev>:NTRansition
................................................................ 895
STATus:QUEStionable:PTRansition
................................................................................. 896
STATus:QUEStionable:INTegrity:PTRansition
....................................................................896
STATus:QUEStionable:INTegrity:HARDware:PTRansition
.................................................. 896
STATus:QUEStionable:LIMit<Lev>:PTRansition
................................................................ 896
................................................................................................ 896
VNA Command Reference
www.allice.de
Allice Messtechnik GmbH