VNA GUI Reference
R&S
®
ZNL/ZNLE
368
User Manual 1178.5966.02 ─ 07
Background information
Refer to the following sections:
●
Chapter 8.3.5, "Unbalance-Balance Conversion"
●
Chapter 8.3.5.1, "Balanced Port Configurations"
●
Chapter 8.3.6, "Reference Impedances"
Predefined Config Tab
The "Predefined Config" tab of the "Balanced Ports" dialog provides the most com-
monly used logical port configurations of the analyzer.
The port configurations are arranged in the list to the right. The resulting port assign-
ment is shown on the left-hand side of the "Predefined Config" tab.
●
For a single-ended port, the diagram shows a single line between the physical test
port and the logical port.
●
For a balanced port, two physical ports are combined to form a single logical port.
●
For unused ports, the physical port is crossed out; no logical port number is
assigned.
Select Predefined Port
Allows you to select from a set of predefined logical port configurations.
Remote command:
SOURce<Ch>:LPORt<LogPt>
SOURce<Ch>:LPORt<LogPt>:CLEar
User Config Tab
The "User Config" tab of the "Balanced Ports" dialog defines a new balanced port con-
figuration.
Meas Softtool
www.allice.de
Allice Messtechnik GmbH