Command Reference
R&S
®
ZNL/ZNLE
668
User Manual 1178.5966.02 ─ 07
Parameters:
<Boolean>
ON | OFF - statistical info field on or off.
*RST:
OFF
Example:
CALCulate<Chn>:STATistics[:STATe]
Manual operation:
CALCulate:TRANsform...
The
CALCulate:TRANsform...
commands convert measured data from one repre-
sentation to another and control the transformation into the time domain (see
ter 8.7.1, "Time Domain Analysis"
CALCulate<Chn>:TRANsform:COMPlex
.......................................................................... 668
CALCulate<Chn>:TRANsform:IMPedance:RNORmal
........................................................ 669
CALCulate<Chn>:TRANsform:TIME[:TYPE]
..................................................................... 669
CALCulate<Chn>:TRANsform:TIME:CENTer
.................................................................... 670
CALCulate<Chn>:TRANsform:TIME:DCHebyshev
............................................................ 670
CALCulate<Chn>:TRANsform:TIME:LPASs
......................................................................671
CALCulate<Chn>:TRANsform:TIME:LPASs:DCSParam
.....................................................671
CALCulate<Chn>:TRANsform:TIME:LPASs:DCSParam:CONTinuous
................................. 672
CALCulate<Chn>:TRANsform:TIME:LPASs:DCSParam:EXTRapolate
................................ 672
CALCulate<Chn>:TRANsform:TIME:LPFRequency
........................................................... 673
CALCulate<Chn>:TRANsform:TIME:RESolution:EFACtor
.................................................. 673
CALCulate<Chn>:TRANsform:TIME:SPAN
.......................................................................673
CALCulate<Chn>:TRANsform:TIME:STARt
...................................................................... 674
CALCulate<Chn>:TRANsform:TIME:STATe
...................................................................... 674
CALCulate<Chn>:TRANsform:TIME:STIMulus
..................................................................675
CALCulate<Chn>:TRANsform:TIME:STOP
.......................................................................675
CALCulate<Chn>:TRANsform:TIME:WINDow
...................................................................675
CALCulate<Chn>:TRANsform:TIME:XAXis
.......................................................................676
CALCulate<Chn>:TRANsform:COMPlex
<Result>
Converts S-parameters into converted (matched-circuit) Y-parameters or Z-parameters
and vice versa, assuming that port no. i is terminated with Z
0i
so that the three parame-
ter sets are equivalent and the following formulas apply:
ii
ii
i
ii
S
S
Z
Z
1
1
0
,
,
2
0
0
0
0
j
i
Z
Z
S
Z
Z
Z
j
i
ij
j
i
ij
ii
ii
ii
i
ii
Z
S
S
Z
Y
/
1
1
1
1