VNA GUI Reference
R&S
®
ZNL/ZNLE
499
User Manual 1178.5966.02 ─ 07
CALCulate<Ch>:TRANsform:VNETworks:BALanced:EMBedding<LogPt>:
PARameters:C<Cmp>
CALCulate<Ch>:TRANsform:VNETworks:BALanced:EMBedding<LogPt>:
PARameters:L<Cmp>
CALCulate<Ch>:TRANsform:VNETworks:BALanced:EMBedding<LogPt>:
PARameters:R<Cmp>
CALCulate<Ch>:TRANsform:VNETworks:BALanced:EMBedding<LogPt>:
PARameters:G<Cmp>
D1, D2
The "D1" and "D2" buttons are enabled as long as the selected
subnetworks that are defined via two-port or four-port Touchstone files (
*.s2p
,
*.s4p
).
When loading a touchstone file, the analyzer by default assumes odd ports left (VNA
side), even ports right (DUT side). However, it is also possible to instruct the analyzer
to assume an "Increasing Port Sequence", i.e. that the low port numbers are on the
VNA side. Furthermore it is possible to "Swap Gates", i.e. to instruct the analyzer to
swap the VNA and DUT side.
Note:
The loaded file is stored in the active channel setup. Persisted channel setups
contain the full (de-)embedding data so that they can be transferred to other instru-
ments.
Remote command:
MMEMory:LOAD:VNETworks<Ch>:BALanced:DEEMbedding<LogPt>
MMEMory:LOAD:VNETworks<Ch>:BALanced:EMBedding<LogPt>
9.14.7
Ground Loop Tab
Allows you to specify a 1-port ground loop deembedding/embedding network.
Such a network is either defined
●
via its S-parameter stored in a one-port Touchstone file (
*.s1p
) or
●
by selecting a predefined lumped element model (Shunt L or Shunt C) and specify-
ing the available parameters (resistance/inductance or resistance/capacitance)
Use the complementary dock widget to activate or deactivate ground loop dembed-
ding/embedding for selected ports (see
Chapter 9.14.1.6, "Ground Loop Panel"
Offset Embed Softtool
www.allice.de
Allice Messtechnik GmbH