Command Reference
R&S
®
ZNL/ZNLE
627
User Manual 1178.5966.02 ─ 07
Parameters:
<Boolean>
ON | OFF - range limit lines on or off.
*RST:
OFF
Example:
See
CALCulate<Chn>:STATistics:DOMain:USER
Manual operation:
See
CALCulate<Chn>:MARKer<Mk>:FUNCtion:DOMain:USER:STARt
<StarSearchRange>
CALCulate<Chn>:MARKer<Mk>:FUNCtion:DOMain:USER:STOP
<StopSearchRange>
These commands define the start and stop values of the search range selected via
CALCulate<Chn>:MARKer<Mk>:FUNCtion:DOMain:USER[:RANGe]
.
Suffix:
<Chn>
.
Channel number used to identify the active trace
<Mk>
Marker number.
Parameters:
<StopSearchRange> Beginning or end of the search range.
Range:
Maximum allowed sweep range, depending on the
instrument model and on the sweep type.
Default unit: NN
Example:
See
CALCulate<Chn>:MARKer<Mk>:FUNCtion:DOMain:
Manual operation:
See
CALCulate<Chn>:MARKer<Mk>:FUNCtion:EXECute
[<SearchMode>]
Selects a search mode for marker no.
<Mk>
and initiates the search. The marker must
be created before using
CALCulate<Chn>:MARKer<Mk>[:STATe]
(exception:
bandfilter search).
Suffix:
<Chn>
.
Channel number used to identify the active trace
<Mk>
Marker number. For a bandfilter search (
BFILter
) this numeric
suffix is ignored and may be set to any value because the band-
filter search functions always use markers M1 to M4.
Setting parameters:
<SearchMode>
MAXimum | MINimum | RPEak | LPEak | NPEak | TARGet |
LTARget | RTARget | BFILter | MMAXimum | MMINimum |
SPRogress
See list of parameters below.
VNA Command Reference
www.allice.de
Allice Messtechnik GmbH