CALCulate<Chn>:LIMit:CONTrol:SHIFt
<LimShift>
Shifts an existing limit line in horizontal direction. See also
Suffix:
<Chn>
.
Channel number used to identify the active trace
Setting parameters:
<LimShift>
Offset value for the limit line
Range:
Virtually no restriction for limit segments
Default unit: NN
Example:
*RST; :CALC:LIM:CONT 1 GHZ, 2 GHZ
Define a limit line segment in the stimulus range between 1 GHz
and 2 GHz, using default response values.
CALC:LIM:CONT:SHIF 1; :CALC:LIM:CONT?
Shift the segment by 1 Hz. The modified limit line segment
ranges from
1000000001
(Hz) to
2000000001
(Hz).
Usage:
Setting only
Manual operation:
CALCulate<Chn>:LIMit:DATA
<Type>, <StartStim>, <StopStim>, <StartResp>,
<StopResp>
Defines the limit line type, the stimulus and response values for a limit line with an arbi-
trary number of limit line segments. See
Chapter 8.4.1.1, "Rules for Limit Line Defini-
Note:
In contrast to
CALCulate<Chn>:LIMit:CONTrol[:DATA]
does not overwrite existing limit line segments. The defined segments are appended to
the segment list as new segments.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<Type>
Identifier for the type of the limit line segment:
0
–
limit line segment off, segment defined but no limit check
performed.
1
–
upper limit line segment
2
–
lower limit line segment
Range:
0, 1, 2 (see above)
<StartStim>,
<StopStim>,
<StartResp>,
<StopResp>
Stimulus and response values of the first and last points of the
limit line segment.
The unit of the stimulus values is adjusted to the sweep type of
the active channel (
), the unit of
the ripple limit is adjusted to the format of the active trace
(
).
VNA Command Reference
www.allice.de
Allice Messtechnik GmbH