Example:
Suppose that the active channel setup contains an active trace
no. 1 and that the sweep range for a frequency sweep starts at 1
GHz.
CALC:MARK:REF ON
Create the reference marker and display it in the center of the
sweep range.
CALC:MARK:REF:X 1GHz
Set the reference marker to the beginning of the sweep range.
CALC:MARK:REF:Y?
Query the measurement value at the reference marker position.
Manual operation:
"Mkr <i> Stimulus / Ref Mkr Stimulus"
CALCulate<Chn>:MARKer<Mk>:REFerence:Y
<RefResponseValue>
Sets or gets the (response) value of the related reference marker.
The marker must be created before using
.
Setting this value is only possible in ARBitrary mode (see
. For NORMal and FIXed mode markers it is read-
only.
Suffix:
<Chn>
.
Channel number used to identify the active trace
<Mk>
This numeric suffix is ignored and may be set to any value.
Parameters:
<RefResponseValue> See
Default unit: NN
Example:
CALCulate<Chn>:MARKer<Mk>:REFerence:X
Manual operation:
"Mkr <i> Arb. Response / Ref Mkr Arb. Response"
CALCulate<Chn>:MARKer<Mk>:SEARch:TRACking
<Boolean>
This command is only available if a search mode is active (
...
)
It enables or disables tracking, which causes the search logic of the related marker(s)
to be repeated after each sweep.
Tip:
If the current search mode is a bandfilter or multiple peak search this command
enables or disables the corresponding tracking.