![Rohde & Schwarz 1323.0012.03 User Manual Download Page 699](http://html1.mh-extra.com/html/rohde-and-schwarz/1323-0012-03/1323-0012-03_user-manual_1477777699.webp)
Command Reference
R&S
®
ZNL/ZNLE
699
User Manual 1178.5966.02 ─ 07
CALCulate<Ch>:TRANsform:VNETworks:BALanced:EMBedding<LogPt>:
PARameters:R<Cmp>
<CircuitModel>, <Resistance>
CALCulate<Ch>:TRANsform:VNETworks:BALanced:EMBedding<LogPt>:
PARameters:R<Cmp>?
<CircuitModel>
Specifies the resistance values R1, R2, R3 in the different circuit models for balanced
port embedding.
In the query form, the <Resistance> parameter must be omitted. The command returns
the resistance value for the specified circuit model.
Suffix:
<Ch>
.
Channel number
<LogPt>
Logical port number (balanced port)
<Cmp>
Number of resistance in circuit model. The total number of resis-
tances depends on the selected circuit model.
Parameters:
<Resistance>
Resistance R<Cmp> for the specified circuit model.
Range:
-10 MΩ to 10 MΩ.
Increment: 1 mΩ (1E-3 Ω)
*RST:
0 Ω for all resistances connected in series with an
inductance. 10 MΩ for all resistances connected in
parallel with a capacitance
Default unit: Ω
Parameters for setting and query:
<CircuitModel>
STSL | STSC | SLST | SCST | CSSL | LSSC | CSSC | LSSL |
SLCS | SCLS | SCCS | SLLS | GSSL | LSSG | SLGS | SGLS
Possible circuit models (character data); see
.
Example:
*RST; :SOUR:LPOR1 1,2; :CALC:TRAN:VNET:BAL:EMB:
PAR:R1? CSSL; R2? CSSL; R3? CSSL
Create a balanced port and query the default resistances for the
Serial Cs, shunt L circuit model. The response is
10000000000;10000000000; 0.
CALC:TRAN:VNET:BAL:EMB:PAR:R3 CSSL, 2.2E+3
Increase the resistance R3 to 2.2 kΩ.
Manual operation:
See
CALCulate<Ch>:TRANsform:VNETworks:BALanced:EMBedding<LogPt>:
TNDefinition
<CircuitModel>
Selects the circuit model for balanced port embedding.
Suffix:
<Ch>
.
Channel number
<LogPt>
Logical port number (balanced port)
VNA Command Reference
www.allice.de
Allice Messtechnik GmbH