If you contact the Rohde&Schwarz support to get help for a certain problem, send this
file to the support in order to identify and solve the problem faster.
Return values:
<FileName>
String containing the drive, path and file name of the created
support file, where the file name consists of the following ele-
ments:
<R&S Device ID>
: The unique R&S device ID indicated in the
"Ve Options" information
<CurrentDate>
: The date on which the file is created
(<YYYYMMDD>)
<CurrentTime>
: The time at which the file is created
(<HHMMSS>)
Example:
DIAG:SERV:SINF?
Result:
Usage:
Query only
Manual operation:
See
" Create R&S Support Information "
SYSTem:PASSword[:CENable]
<arg0>
Provides a password for subsequent service functions.
Parameters:
<arg0>
string
Example:
SYST:PASS:CEN '894129'
Manual operation:
See
SYSTem:PASSword:RESet
Clears any previously provided password and returns to the most restrictive service
level.
Manual operation:
See
10.4
VNA Remote Control Basics
10.4.1
Block Data Format
Block data is a transmission format which is suitable for the transmission of large
amounts of data. A command using a block data parameter with definite length has the
following structure:
Example:
HEADer:HEADer #45168xxxxxxxx
The hash symbol # introduces the data block. The next number indicates how many of
the following digits describe the length of the data block. In the example the 4 following
VNA Remote Control Basics
www.allice.de
Allice Messtechnik GmbH