CALCulate<Ch>:TRANsform:VNETworks:GLOop:DEEMbedding:TNDefinition
<CircuitModel>
Selects the circuit model for ground loop deembedding.
Suffix:
<Ch>
.
Channel number.
Parameters:
<CircuitModel>
FIMPort | SL | SC | SG
Possible circuit models (character data); see
ground loop port embedding/deembedding
Example:
See
CALCulate<Ch>:TRANsform:VNETworks:GLOop:
Manual operation:
See
CALCulate<Ch>:TRANsform:VNETworks:GLOop:EMBedding[:STATe]
<Boolean>
Enables or disables the embedding function for ground loops. It is allowed to change
the circuit model and its parameters while embedding is enabled.
Suffix:
<Ch>
.
Channel number.
Parameters:
<Boolean>
ON - Embedding active
OFF - Embedding inactive
*RST:
OFF
Example:
CALC:TRAN:VNET:GLO:EMB:TND SL
Select the Shunt L circuit model for embedding.
CALC:TRAN:VNET:GLO:EMB:PAR:R SL, 2.2E+3; :CALC:
TRAN:VNET:GLO:EMB ON
Increase the resistance for the Shunt L circuit model to 2.2 kΩ
and enable embedding.
Manual operation:
See
CALCulate<Ch>:TRANsform:VNETworks:GLOop:EMBedding:PARameters:C
<CircuitModel>, <Capacitance>
CALCulate<Ch>:TRANsform:VNETworks:GLOop:EMBedding:PARameters:C?
<CircuitModel>
Specifies the capacitance value C in the different circuit models for ground loop
embedding.