Command Reference
R&S
®
ZNL/ZNLE
921
User Manual 1178.5966.02 ─ 07
Usage:
Event
CALCulate<Chn>:MARKer<Mk>:SEARch:LEFT
CALCulate<Chn>:MARKer<Mk>:SEARch:NEXT
CALCulate<Chn>:MARKer<Mk>:SEARch:RIGHt
These commands selects a search mode for marker no.
<Mk>
and initiate a search for
the next valid peak to the left, the next highest or lowest value among the valid peaks,
and the next valid peak to the right. The marker must be created before using
CALCulate<Chn>:MARKer<Mk>[:STATe]
.
Note:
These commands are the ZVR-compatible equivalents of
LPEak | NPEak | RPEak
.
Suffix:
<Chn>
.
Channel number used to identify the active trace.
<Mk>
Marker number.
Usage:
Event
CALCulate<Chn>:MARKer<Mk>:SEARch[:IMMediate]
Initiates a search according to the search function selected with
. The marker must be created before using
CALCulate<Chn>:MARKer<Mk>[:STATe]
.
Note:
Together with
CALCulate<Chn>:MARKer<Mk>:FUNCtion[:SELect]
command is the ZVR-compatible equivalent of
Suffix:
<Chn>
.
Channel number used to identify the active trace.
<Mk>
Marker number. For a bandfilter search (
BFILter
) this numeric
suffix is ignored and may be set to any value because the band-
filter search functions always use markers M1 to M4.
Usage:
Event
CALCulate<Chn>:MATH[:EXPRession][:DEFine]
<Expression>
Defines a simple mathematical relation between traces. To calculate and display the
new mathematical trace, the mathematical mode must be switched on
(
CALCulate<Chn>:MARKer<Mk>[:STATe]
).
Note:
This command places some restrictions on the mathematical expression and the
operands. Use
CALCulate<Chn>:MATH[:EXPRession]:SDEFine
expressions.
Suffix:
<Chn>
.
Channel number used to identify the active trace.
VNA Command Reference
www.allice.de
Allice Messtechnik GmbH