SYSTem:COMMunicate:AKAL:CONNection
......................................................................897
SYSTem:COMMunicate:AKAL:MMEMory[:STATe]
............................................................. 897
SYSTem:COMMunicate:GPIB[:SELF]:DCLear:SUPPress
...................................................898
SYSTem:COMMunicate:GPIB[:SELF]:INIT:WAIT
............................................................... 898
SYSTem:COMMunicate:GPIB[:SELF]:LPORt:ALIGn
..........................................................898
SYSTem:COMMunicate:NET:HOSTname
......................................................................... 899
SYSTem:COMMunicate:RDEVice:AKAL:ADDRess
............................................................899
SYSTem:COMMunicate:RDEVice:AKAL:ADDRess:ALL?
................................................... 899
SYSTem:COMMunicate:RDEVice:AKAL:CKIT:CATalog?
.................................................... 899
SYSTem:COMMunicate:RDEVice:AKAL:CKIT:STANdard:CATalog?
.................................... 900
SYSTem:COMMunicate:RDEVice:AKAL:DATE?
................................................................901
SYSTem:COMMunicate:RDEVice:AKAL:FRANge?
............................................................901
SYSTem:COMMunicate:RDEVice:AKAL:PORTs?
.............................................................. 902
SYSTem:COMMunicate:RDEVice:AKAL:PREDuction[:STATe]
............................................ 902
SYSTem:COMMunicate:RDEVice:AKAL:SDATa?
.............................................................. 902
SYSTem:COMMunicate:RDEVice:AKAL:WARMup[:STATe]?
...............................................903
SYSTem:COMMunicate:AKAL:CONNection
<CalStandard>, <Port>[, <SecondPort>,
<CalkitIndex>]
Connects the selected calibration standard to one or two ports of the active calibration
unit (see
SYSTem:COMMunicate:RDEVice:AKAL:ADDRess
Setting parameters:
<CalStandard>
THRough | OPEN | SHORt | MATCh
Connected one or two-port standard
<Port>
Port number of the calibration unit, for one and two-port stand-
ards.
<SecondPort>
Second port number of the calibration unit.
For two-port standards (THRough) this parameter must be provi-
ded, for one-port standards (OPEN | SHORt | MATCh) it must be
omitted.
<CalkitIndex>
For calibration units that are equipped with more than one cali-
bration kit, this parameter indicates the 1-based index of the cal
kit to be used (mandatory!).
For other calibration units, this parameter is optional, but if it is
provided, it must be set to 1.
Example:
SYST:COMM:AKAL:CONN THR, 1, 2
Connect a through standard between ports 1 and 2 of the cal
unit.
Usage:
Setting only
Manual operation:
See
SYSTem:COMMunicate:AKAL:MMEMory[:STATe]
<Boolean>
Shows or hides the memory of the active calibration unit (see
COMMunicate:RDEVice:AKAL:ADDRess