VNA GUI Reference
R&S
®
ZNL/ZNLE
406
User Manual 1178.5966.02 ─ 07
A ripple test is a special type of limit test where the
difference
between response val-
ues in certain stimulus ranges must not exceed configurable limits (ripple limits).
Ripple limits can be defined for cartesian trace formats only and are limited to the trace
format they were configured for. If another format is selected, the ripple limit lines are
hidden and the limit check is temporarily disabled.
Background information
Refer to
9.9.5.1
Controls on the Ripple Test Tab
The "Def. Ripple Test..." button opens the "Define Ripple Test" dialog (see
ter 9.9.5.2, "Define Ripple Test Dialog"
Show Ripple Limits
Shows or hides the ripple limit lines associated with the active trace in a Cartesian dia-
gram area. The vertical positions of the ripple lines are recalculated after each sweep;
only their stimulus range and distance (the ripple limit) are fixed.
Note:
Display of the limit line and limit check are independent of each other: Hiding the
limit line does not switch off the limit check.
Remote command:
CALCulate<Chn>:RIPPle:DISPlay[:STATe]
Display Lines Softtool
www.allice.de