Install Additional Hardware
Add a TN2501AP Announcement Circuit Pack
SI Installation and Upgrades
579
June 2004
Configuring the system for the TN2501AP
1
At the SAT, type
list configuration board board-location
and press Enter.
The System Configuration report appears. Use this report to ensure that the switch recognizes the
TN2501AP circuit pack after it is latched in the carrier slot.
2
Verify the following field values:
—
Board Type
shows
VAL-ANNOUNCEMENT
—
Code
is
TN2501AP
3
At the SAT, type
change node-names ip
and press Enter.
The IP Node Names screen appears. Use this screen to administer the circuit pack’s node name.
4
Type a unique name in the
Name
field.
This name is recognized only within the switch, and does not need to match the node name on
your network.
5
Enter the
IP Address
.
You can get this information from the network manager.
6
Press Enter to save the changes.
7
Type
change ip-interfaces
and press Enter.
The IP Interfaces screen appears. Use this screen to administer an
IP interface
, which
associates the circuit pack with an IP address.
8
Set the
Enable Eth Pt
field to y.
9
Set the
Type
field to VAL.
10
Type the circuit pack location in the
Slot
field (UUCSS).
If a TN2501AP circuit pack is not at this location when you submit the screen, the system prompts
you to enter a VAL circuit pack location.
11
In the
Node Name
field, enter the Node Name you entered in
Step 4
.
If you press Help, a list of administered node names appears (including the name you
administered with the
change node-names ip
command), and you can select from the list.
12
Set the
Subnet Mask
field according to your network requirements.
Gateway Address
is usually the same as the TN2501AP circuit pack’s IP address, usually
with the fourth octet changed. Be sure to set this address according to your network requirements.
13
Press Enter to save the changes.
14
Type
add data-module
extension
and press Enter.
The Data Module screen appears. Use this screen to administer the data module that is associated
with the TN2501AP ethernet port.
15
Set the
Type
field to ethernet.
16
Set the
Port
field to correspond to the circuit pack location.
The port number (final two digits) is always 33 for the TN2501AP circuit pack.
17
Set the
Link
field to an unassigned or next-available link number.
18
Set the
Network uses 1’s for Broadcast Address
field according to the your
network requirements.
19
Type a unique name in the
Name
field.
Содержание MCC1
Страница 38: ...Upgrades to Avaya Commnication Manager Made Easy Before you start 38 SI Installation and Upgrades June 2004 ...
Страница 326: ...Installation for MCC1 Multicarrier Cabinets Made Easy 326 SI Installation and Upgrades June 2004 ...
Страница 362: ... Single Carrier Cabinets Made Easy 362 SI Installation and Upgrades June 2004 ...
Страница 498: ...Test the System LED Indicators 498 SI Installation and Upgrades June 2004 ...
Страница 650: ...Add IP Solutions Task list Upgrade a TN802 to a TN802B 650 SI Installation and Upgrades June 2004 ...
Страница 692: ...Install and Administer Trunks Add TN1654 DS1 Converter r only 692 SI Installation and Upgrades June 2004 ...
Страница 770: ...Connecting and Handling Fiber Optic Cables Cleaning Fiber Optic Cables 770 SI Installation and Upgrades June 2004 ...
Страница 784: ...Connector and Cable Diagrams Pinout Charts DS1 Interface Cable H600 307 784 SI Installation and Upgrades June 2004 ...
Страница 792: ...UPS Installation for SCC1 EPN A Carrier Cabinet Task List Install UPS 792 SI Installation and Upgrades June 2004 ...
Страница 874: ...Index Z 874 SI Installation and Upgrades June 2004 ...