Install Additional Hardware
Administer TN464GP/TN2464BP with Echo Cancellation
598
SI Installation and Upgrades
June 2004
Administer DCS (Add DCS)
Return to Task List
1
Administer the required translation data using the screens listed under Distributed
Communications System (DCS) in the Administrator’s Guide for Avaya™ Communication
Manager.
Save Translations (Add DCS)
Return to Task List
1
If the system is high- or critical-reliability, type
status spe
and press Enter
to verify that the
standby SPE is refreshed and that the standby disk is in service.
2
Type
save translation
[
spe-a or both
]
disk
and press Enter. This command instructs the system
to take all translation information in memory and write it to the disk(s).
Administer TN464GP/TN2464BP with Echo
Cancellation
Return to Task List
This section provides information about the TN464GP and TN2464BP circuit packs with echo
cancellation and the procedure to
Administer TN464GP/TN2464BP
on page 599.
The TN464GP and TN2464BP circuit packs with echo cancellation are intended for DEFINITY
customers who are likely to encounter echo over circuits connected to the Direct Distance Dialing (DDD)
network. These circuit packs are intended for channels supporting voice; therefore, they support the
following trunks: CAS, CO, DID, DIOD, DMI, FX, Tie, WATS. They do not support any data trunk
groups.
NOTE:
The P suffix designation means the circuit pack is programmable; new firmware can be
downloaded directly to the circuit pack. For more information, see
Upgrade Firmware on
Programmable Circuit Packs
on page 715.
The TN464GP and TN2464BP circuit packs are backwards compatible, although the echo cancellation
feature can be used only with Release 1.1 or later of Avaya™ Communication Manager and after the
feature is enabled.
The echo cancellation feature cancels echoes with delays up to 96 ms. Echo cancellation is disabled
automatically when the circuit pack detects a 2100-Hz phase-reversed tone put out by high-speed
modems (56 kbaud) but not when it detects a 2100-Hz straight tone generated by low-speed modems (9.6
kbaud).
For information on installing port circuit packs, see
Add Port Circuit Packs
on page 567. For information
on setting the option switches, see
Option Switch Settings
on page 741.
Echo cancellation must first be purchased, then added to the system via a new License File.
Return to Task List
Содержание MCC1
Страница 38: ...Upgrades to Avaya Commnication Manager Made Easy Before you start 38 SI Installation and Upgrades June 2004 ...
Страница 326: ...Installation for MCC1 Multicarrier Cabinets Made Easy 326 SI Installation and Upgrades June 2004 ...
Страница 362: ... Single Carrier Cabinets Made Easy 362 SI Installation and Upgrades June 2004 ...
Страница 498: ...Test the System LED Indicators 498 SI Installation and Upgrades June 2004 ...
Страница 650: ...Add IP Solutions Task list Upgrade a TN802 to a TN802B 650 SI Installation and Upgrades June 2004 ...
Страница 692: ...Install and Administer Trunks Add TN1654 DS1 Converter r only 692 SI Installation and Upgrades June 2004 ...
Страница 770: ...Connecting and Handling Fiber Optic Cables Cleaning Fiber Optic Cables 770 SI Installation and Upgrades June 2004 ...