System 75 XE to R8si (Blowback)
Task List: System 75 XE to R8si
SI Installation and Upgrades
247
June 2004
Install circuit packs into the port cabinets [75 XE upgrade]
Return to Task List
!
WARNING:
Before inserting or removing a circuit pack from a cabinet, put on a wrist strap and attach
its plug or clip to the cabinet’s frame.
!
WARNING:
The replaced port circuit packs must conform to the usable vintage requirements for a
Release 8si system (see Reference Guide for Circuit-Pack Vintages and Change Notices).
1
Using the label and the annotated
list configuration all
printout (provided with the Release 8si
translation memory card), install the Release 8si control circuit packs into the new enhanced
control cabinet(s) or the expansion control cabinet, as appropriate.
NOTE:
You can use a TN756 Tone Detector/Generator in an upgraded PPN system. You can not
use the TN756 in an EPN upgrade. If a TN756 is being replaced by a new tone-clock
during the upgrade, you will replace this circuit pack either with a TN2182 tone-
clock/tone detector or with both a new Release 8si tone-clock (TN768 or TN780) and a
new tone detector (TN748B).
2
Reinstall the previously-removed port circuit packs into the A cabinet using the decal and the
annotated
list configuration all
printout (provided with the Release 8si translation memory card)
as a guide.
NOTE:
If a TN2182 is installed, do not reintstall the TN756 in the port network.
You do not need to move and retranslate these circuit packs. The new Release 8si enhanced
control cabinet has 2 or 3 more port slots than the System 75 control cabinet you removed.
Return to Task List
Change cabinet address plugs [75 XE upgrade]
Return to Task List
If a duplicated control cabinet was added to position B and did not replace a port cabinet, the upgraded
PPN’s port cabinets occupy different positions in the cabinet stack. You must change the location of each
port cabinet’s address plug to reflect the cabinet’s current position (see
Figure 50, Cabinet address-plug
location,
on page 248).
The cabinet address plug-pins are to the right of the pin-field block for slot 00. For each port cabinet,
attach the address plug to the pair of backplane pins corresponding to the cabinet’s position in the stack.
Содержание MCC1
Страница 38: ...Upgrades to Avaya Commnication Manager Made Easy Before you start 38 SI Installation and Upgrades June 2004 ...
Страница 326: ...Installation for MCC1 Multicarrier Cabinets Made Easy 326 SI Installation and Upgrades June 2004 ...
Страница 362: ... Single Carrier Cabinets Made Easy 362 SI Installation and Upgrades June 2004 ...
Страница 498: ...Test the System LED Indicators 498 SI Installation and Upgrades June 2004 ...
Страница 650: ...Add IP Solutions Task list Upgrade a TN802 to a TN802B 650 SI Installation and Upgrades June 2004 ...
Страница 692: ...Install and Administer Trunks Add TN1654 DS1 Converter r only 692 SI Installation and Upgrades June 2004 ...
Страница 770: ...Connecting and Handling Fiber Optic Cables Cleaning Fiber Optic Cables 770 SI Installation and Upgrades June 2004 ...
Страница 784: ...Connector and Cable Diagrams Pinout Charts DS1 Interface Cable H600 307 784 SI Installation and Upgrades June 2004 ...
Страница 792: ...UPS Installation for SCC1 EPN A Carrier Cabinet Task List Install UPS 792 SI Installation and Upgrades June 2004 ...
Страница 874: ...Index Z 874 SI Installation and Upgrades June 2004 ...