Install and Wire Telephones
DS1 Tie Trunk Example
508
SI Installation and Upgrades
June 2004
DS1 Tie Trunk Example
Return to Task List
Digital Signal Level 1 (DS1) tie trunks provide a 1.544 Mbps (T1) or 2.048 Mbps (E1) digital data
service between two collocated systems or between the system and a data network.
See these examples:
•
Collocated DS1 Tie Trunks
on page 508
•
DS1 Tie Trunks Using T1 Channel Service Unit
on page 508
For cable descriptions, see
•
DS1 Cables
on page 509
•
Pinout of C6F Cable
on page 510
Collocated DS1 Tie Trunks
Two DS1 tie trunk circuit packs can be in collocated systems. A DS1 Tie Trunk circuit pack in one
system can be connected to a DS1 in another system. A C6D cable can be used if the distance is less than
50 feet (15.2 m). If the distance is between 50 feet (15.2 m) and 1310 feet (399 m), use a C6E cable.
NOTE:
The maximum distance between cabinets is 1310 feet (399.3 m).
DS1 Tie Trunks Using T1 Channel Service Unit
The T1 Channel Service Unit (CSU) interfaces the DS1 tie trunks with the 1.544 Mbps digital facility.
Connect the DS1 tie trunk to a T1 CSU. See
Figure 197, Typical Connections to Channel Service Unit,
on
page 509.
NOTE:
A 3150 CSU is shown, a 120A Integrated CSU (ICSU) may be used.
Contact your Avaya representative for maximum cabling distances for the 31xx series CSU or the 120A
ICSU.
Содержание MCC1
Страница 38: ...Upgrades to Avaya Commnication Manager Made Easy Before you start 38 SI Installation and Upgrades June 2004 ...
Страница 326: ...Installation for MCC1 Multicarrier Cabinets Made Easy 326 SI Installation and Upgrades June 2004 ...
Страница 362: ... Single Carrier Cabinets Made Easy 362 SI Installation and Upgrades June 2004 ...
Страница 498: ...Test the System LED Indicators 498 SI Installation and Upgrades June 2004 ...
Страница 650: ...Add IP Solutions Task list Upgrade a TN802 to a TN802B 650 SI Installation and Upgrades June 2004 ...
Страница 692: ...Install and Administer Trunks Add TN1654 DS1 Converter r only 692 SI Installation and Upgrades June 2004 ...
Страница 770: ...Connecting and Handling Fiber Optic Cables Cleaning Fiber Optic Cables 770 SI Installation and Upgrades June 2004 ...
Страница 784: ...Connector and Cable Diagrams Pinout Charts DS1 Interface Cable H600 307 784 SI Installation and Upgrades June 2004 ...
Страница 792: ...UPS Installation for SCC1 EPN A Carrier Cabinet Task List Install UPS 792 SI Installation and Upgrades June 2004 ...
Страница 874: ...Index Z 874 SI Installation and Upgrades June 2004 ...