Connect a 25-pair cable from the AUX connector on the back of the control carrier to a connecting block
on the trunk/auxiliary field.
Table 21, Auxiliary Lead Appearances at AUX Connector,
on page 511 shows the Control Carrier outputs
cable pinouts. The Control Carrier AUX connector outputs include:
•
Alarm monitoring for the auxiliary cabinet
•
Seven -48 VDC power sources for emergency transfer units
•
Three -48 VDC power sources for remotely powering three attendant consoles or telephone
adjuncts
•
The remote management terminal interface trunk connection location
•
A relay contact that actuates a customer-supplied light, bell, or similar device. The relay can
activate when a major, minor, or warning condition occurs. The device connected to the alarm
leads must not exceed a rating of 30 VAC rms or 60 VDC at 0l75 amps.
Table 21
shows the pinouts for an external alarm.
Table 22, Port Circuit Pack and Telephone Pin Designations,
on page 513 provides port circuit pack and
telephone pin designations.
Pinout of C6F Cable
Wire Color
Lead
Designation
Pin
Number
White/Green
L
I
* (High Side)
47
Green
L
I
22
White/Brown
LO
48
Brown
LO* (High Side)
23
White/Slate
LBACK2
49
Slate
LBACK1
24
Содержание MCC1
Страница 38: ...Upgrades to Avaya Commnication Manager Made Easy Before you start 38 SI Installation and Upgrades June 2004 ...
Страница 326: ...Installation for MCC1 Multicarrier Cabinets Made Easy 326 SI Installation and Upgrades June 2004 ...
Страница 362: ... Single Carrier Cabinets Made Easy 362 SI Installation and Upgrades June 2004 ...
Страница 498: ...Test the System LED Indicators 498 SI Installation and Upgrades June 2004 ...
Страница 650: ...Add IP Solutions Task list Upgrade a TN802 to a TN802B 650 SI Installation and Upgrades June 2004 ...
Страница 692: ...Install and Administer Trunks Add TN1654 DS1 Converter r only 692 SI Installation and Upgrades June 2004 ...
Страница 770: ...Connecting and Handling Fiber Optic Cables Cleaning Fiber Optic Cables 770 SI Installation and Upgrades June 2004 ...
Страница 784: ...Connector and Cable Diagrams Pinout Charts DS1 Interface Cable H600 307 784 SI Installation and Upgrades June 2004 ...
Страница 792: ...UPS Installation for SCC1 EPN A Carrier Cabinet Task List Install UPS 792 SI Installation and Upgrades June 2004 ...
Страница 874: ...Index Z 874 SI Installation and Upgrades June 2004 ...