Release 9si/10si/Communication Manager 1.x to Communication Manager 2.1
Task list: R9si/10si/Communication Manager 1.x to Communication Manager 2.1
46
SI Installation and Upgrades
June 2004
Check SPE
Return to Task List
1
Type
status system 1
and press Return.
Check these fields for the corresponding values:
— Maj/Min alarms = 0
— Service State = in service
Return to Task List
Verify the software version
Return to Task List
1
Type
list configuration software-version
and press Return.
The Software Versions screen appears.
2
In the UPDATE FILE section, check the
Update State
field for a software patch:
— If there is a patch number, then a patch has been applied.
— If the field is none in memory, there is no software patch in system memory.
If you need to restore the system to the old software version, you must also download a patch onto
the system.
3
In the SOFTWARE VERSION section note the current software version listed in the
Memory
Resident
field.
Ensure that the current software version is compatible with this software-only upgrade path.
Return to Task List
Verify system status
Return to Task List
1
Type
status system 1
and press Return.
Check these fields for the corresponding values:
— In the SPE ALARMS section,
MAJOR
and
MINOR alarms
= 0
—
Service State
= in service
2
If there are alarms, take the necessary corrective actions (
display alarms
).
3
Type
display errors
and press Return.
4
Examine the Hardware Error Log and record any Error Code 18 alarm that identifies existing
busyouts. After the upgrade you will restore the busyouts as they were (
Restore busyouts
).
5
For configurations with existing BX.25 links that are being retained after the upgrade, type
display communication-interface links
and press Return.
Содержание MCC1
Страница 38: ...Upgrades to Avaya Commnication Manager Made Easy Before you start 38 SI Installation and Upgrades June 2004 ...
Страница 326: ...Installation for MCC1 Multicarrier Cabinets Made Easy 326 SI Installation and Upgrades June 2004 ...
Страница 362: ... Single Carrier Cabinets Made Easy 362 SI Installation and Upgrades June 2004 ...
Страница 498: ...Test the System LED Indicators 498 SI Installation and Upgrades June 2004 ...
Страница 650: ...Add IP Solutions Task list Upgrade a TN802 to a TN802B 650 SI Installation and Upgrades June 2004 ...
Страница 692: ...Install and Administer Trunks Add TN1654 DS1 Converter r only 692 SI Installation and Upgrades June 2004 ...
Страница 770: ...Connecting and Handling Fiber Optic Cables Cleaning Fiber Optic Cables 770 SI Installation and Upgrades June 2004 ...
Страница 784: ...Connector and Cable Diagrams Pinout Charts DS1 Interface Cable H600 307 784 SI Installation and Upgrades June 2004 ...
Страница 792: ...UPS Installation for SCC1 EPN A Carrier Cabinet Task List Install UPS 792 SI Installation and Upgrades June 2004 ...
Страница 874: ...Index Z 874 SI Installation and Upgrades June 2004 ...