Adjuncts and Peripherals
DS1/T1 CPE loopback jack
820
SI Installation and Upgrades
June 2004
Running the data test
1
Display the bit error count. At the management terminal, enter
list meas ds1 sum location
.
2
Step through
Table 44
to troubleshoot.
3
Once you are fairly certain that the test is reporting no errors (after at least 1 error-free minute),
confirm that the 3-in-24 pattern error detector is operating. Enter
test ds1-loop location
inject-single-bit-error
.
4
Display the bit error count again. At the management terminal, enter
list meas ds1 sum
location
.
Table 44: DS1 Troubleshooting
Condition
Solution
The value of the
Test: cpe-loopback-
jack
field
is
Pattern 3-in-24
The loopback jack test is active.
The value of the
Synchronized
field is
N
Retry the test 5 times.
The value of the
Synchronized
field
remains
N
after 5 tries.
Excessive bit errors are likely. Check for
intermittent connections or broken wires in an
SPE receive or transmit pair, and repair as
necessary. Then repeat
Step 1
.
The value of the
Bit-error count
field
is non-zero
Repeat
Step 1
several times.
The value of the
Synchronized
field is
Y
The DS1 circuit pack has synchronized to the
looped 3-in-24 pattern and is counting bit errors
in the pattern.
The value of the
Bit-error count
field
pegs at
75535
or increments by 100s or 1000s
each time you repeat
Step 1
.
Suspect loose or corroded connections, severe
crosstalk, or impedance imbalances between the
two conductors of the receive or transmit pair.
Wiring may need replacement.
The value of the
Bit-error count
field
is
0
There are no obvious wiring problems. Verify this
by repeating
Step 1
at 1-minute to
10-minute intervals until you are certain.
If the test reports no errors for 1 minute, the error
rate is less than 1 in 10
8
. If the test reports no
errors for 10 minutes, the error rate is less than 1
in 10
9
.
Condition
Solution
The value of the
Bit-error count
field is
greater than 1
Replace the ICSU, and retest.
The value of the
Bit-error count
field is
still greater than 1 after you replace the ICSU.
Replace the DS1 circuit pack, and retest.
The value of the
Bit-error count
field is
1
The test passed.
Содержание MCC1
Страница 38: ...Upgrades to Avaya Commnication Manager Made Easy Before you start 38 SI Installation and Upgrades June 2004 ...
Страница 326: ...Installation for MCC1 Multicarrier Cabinets Made Easy 326 SI Installation and Upgrades June 2004 ...
Страница 362: ... Single Carrier Cabinets Made Easy 362 SI Installation and Upgrades June 2004 ...
Страница 498: ...Test the System LED Indicators 498 SI Installation and Upgrades June 2004 ...
Страница 650: ...Add IP Solutions Task list Upgrade a TN802 to a TN802B 650 SI Installation and Upgrades June 2004 ...
Страница 692: ...Install and Administer Trunks Add TN1654 DS1 Converter r only 692 SI Installation and Upgrades June 2004 ...
Страница 770: ...Connecting and Handling Fiber Optic Cables Cleaning Fiber Optic Cables 770 SI Installation and Upgrades June 2004 ...
Страница 784: ...Connector and Cable Diagrams Pinout Charts DS1 Interface Cable H600 307 784 SI Installation and Upgrades June 2004 ...
Страница 792: ...UPS Installation for SCC1 EPN A Carrier Cabinet Task List Install UPS 792 SI Installation and Upgrades June 2004 ...
Страница 874: ...Index Z 874 SI Installation and Upgrades June 2004 ...