background image

MI00555-1-EN

INSTALLATION MANUAL

1/4

INSTALLATION MANUAL

SENECA s.r.l.; Via Austria, 26 – 35127 – PADOVA – ITALY; Tel.  +39.049.8705359  -  Fax +39.049.8706287

R-PASS

DOCUMENTATION

PRELIMINARY WARNINGS

The word 

WARNING

 preceded by the symbol 

 indicates conditions or actions that put the user’s safety at 

risk. The word 

ATTENTION

 preceded by the symbol 

 indicates conditions or actions that might damage the 

instrument or the connected equipment. The warranty shall become null and void in the event of improper use or 

tampering with the module or devices supplied by the manufacturer as necessary for its correct operation, and if 

the instructions contained in this manual are not followed.

WARNING

: The full content of this manual must be read before any operation.

The module must only be used by qualified electricians.

Specific documentation is available using the QR-CODE shown on page 1.

Electrical and electronic waste disposal (applicable in the European Union and other countries with recycling).

The symbol on the product or its packaging shows the product must be surrendered to a collection centre 

authorized to recycle electrical and electronic waste.

The module must be repaired and damaged parts replaced by the Manufacturer.

The product is sensitive to electrostatic discharges. Take appropriate measures during any operation.

CONTACT INFORMATION

Technical support

[email protected]

Product information

[email protected]

This document is the property of SENECA srl. Copies and reproduction are prohibited unless authorised.

The content of this document corresponds to the described products and technologies.

Stated data may be modified or supplemented for technical and/or sales purposes.

R-PASS

Содержание R-PASS

Страница 1: ...ration The module must only be used by qualified electricians Specific documentation is available using the QR CODE shown on page 1 Electrical and electronic waste disposal applicable in the European Union and other countries with recycling The symbol on the product or its packaging shows the product must be surrendered to a collection centre authorized to recycle electrical and electronic waste T...

Страница 2: ...hing VPN connection problems SRV On VPN BOX SERVICE connection is working correctly Flashing VPN BOX SERVICE connection in error UPS On UPS active only in the presence of the R COMM accessory Off UPS inactive LOG On Data Logger active and working correctly Flashing Data Logger in error WIFI only R PASS W On WiFi enabled in Station mode Flashing WiFi enabled in access point mode only R PASS W On Wi...

Страница 3: ...Threshold OFF 8V IEC6113 2 Type 1 3 compliant ANALOGUE INPUTS Voltage 0 30Vdc impedance 20kΩ Current 0 25mA impedance 50Ω AUXILIARY VOLTAGE OUTPUT 12Vdc Max 50mA WI FI only R PASS W Integrated WiFi 802 11 b g n 2 4 2 4835GHz band max Output Power 17dBm 50mW ELECTRICAL CONNECTIONS POWER SUPPLY ANALOG INPUT VOLTAGE ANALOG INPUT CURRENT mA mA 55 AI2 53 GND 54 AI1 DIGITAL INPUT DIGITAL OUTPUT PNP DIGI...

Страница 4: ...B 64 A CAN OPEN 53 GND 57 H 56 L COMMON COMMON ETHERNET CONNECTION RULES For the Ethernet cabling between the devices the use of the unshielded CAT5 or CAT5e cable is required FACTORY IP ADDRESS The default module IP address is static 192 168 90 101 WEB SERVER To access the maintenance Web Server with the 192 168 90 101 factory IP address Default user admin Default password admin http 192 168 90 1...

Отзывы: