Line
Description
Tx Power
Present Tx power of the SFP. If this crosses Tx power alarm/
warning thresholds, the Tx power high alarm/warning flag is set
to true. If it falls below the low alarm/warning thresholds, the Tx
power low alarm/ warning flag is set to true.
Rx Power
Present receiving (Rx) power of the SFP. This value is either
average Rx power or OMA. This depends on the Rx Power
measurement type displayed above. If this crosses Rx power
alarm/warning thresholds, the Rx power high alarm/warning flag
is set to true. If it falls below the low alarm/warning thresholds,
the Rx power low alarm/warning flag is set to true.
Data Ready state
Bar
This field indicates that the transceiver has achieved power up
and data is ready. This is set to true if data is ready to be sent and
set to false if data is being transmitted.
Rx LOS state
This is the digital state of the Rx_LOS output pin. This is set to
true if the operating status is down.
Tx Fault state
This is the digital state of the Tx Fault output pin.
Rate Select state
This is the digital state of the SFP rate_select input pin.
RS state
This is the reserved digital state of the pin AS(1) per SFF-8079
and RS(1) per SFF-8431.
Tx Disable state
If the admin status of the port is down, then this flag is set to
true.
Temperature High
Alarm Flag
This can be either true or false, depending on the Current
voltage value displayed above.
Voltage High
Alarm Flag
This can be either true or false, depending on the Current
Temperature value displayed above.
Tx Bias High
Alarm Flag
This can be either true or false, depending on the present Tx bias
current value displayed above.
Tx Power High
Alarm Flag
This can be either true or false, depending on the Current Tx
bias power value displayed above.
Rx Power High
Alarm Flag
This can be either true or false, depending on the Current Rx
power value displayed above.
Temperature Low
Alarm Flag
This can be either true or false, depending on the Current
Temperature value displayed above.
Voltage Low
Alarm Flag
This can be either true or false, depending on the Current
voltage value displayed above.
Tx Bias Low Alarm
Flag
This can be either true or false, depending on the Tx bias current
value displayed above.
Tx Power Low
Alarm Flag
This can be either true or false, depending on the Current Tx
power value displayed above.
Interfaces
998
Summary of Contents for C9000 series
Page 1: ...Dell Networking Command Line Reference Guide for the C9000 Series Version 9 10 0 0 ...
Page 394: ...deny 14551 666 Dell Access Control Lists ACL 394 ...
Page 877: ...algorithm FIPS Cryptography 877 ...
Page 1297: ...Total 5 0 Total 5 active route s using 952 bytes IPv6 Basics 1297 ...