Version
Description
9.9(0.0)
Introduced on the C9010.
9.2(1.0)
Introduced on the Z9500.
8.3.19.0
Introduced on the S4820T.
8.3.12.0
Introduced on the S4810.
8.3.11.1
Introduced on the Z9000.
8.1.1.0
Introduced on the E-Series ExaScale.
7.6.1.0
Introduced on the S-Series.
7.5.1.0
Introduced on the C-Series
E-Series
Original command.
Example
Dell#show debugging
Generic IP:
IP packet debugging is on for
ManagementEthernet 0/0
Port-channel 1-2
Port-channel 5
TenGigabitEthernet 0/0-3,5-6,10-11,20
TenGigabitEthernet 1/0-1,5-6,10-11,15,17,19,21
ICMP packet debugging is on for
TenGigabitEthernet 1/0,2,4,6,8,10,12,14,16
DHCP Server:
DHCP server packet debugging on
Dell#
show environment
View system component status (for example, fan, power supply, and temperature).
C9000 Series
Syntax
show environment [all | fan | linecard
slot-id
| media | pe
pe-id
| pem | thermal-sensors]
From a
PE console
, use
show environment [all | fan | pem | stack-unit |
thermal-sensors]
thermal-sensors
Enter the keyword
thermal-sensors
to display only temperatures and thresholds for
the system and switching core, and port modules.
Parameters
all
Enter the keyword
all
to view all components.