The following is a list of the Dell Networking OS version history for this command.
Version
Description
9.9(0.0)
Introduced on the C9010.
Usage Information The
power inline restore pe
command enables or restores the temporarily
suspended PoE power supply to all the ports on a port extender unit.
Example
Dell#power inline restore pe 1 stack-unit 2
power inline suspend pe
Disable PoE power supply to all the ports in a port extender unit temporarily.
C9000 Series
Syntax
power inline suspend pe
pe-id
stack-unit
unit number
Parameters
pe
pe-id
Enter the keyword
pe
and the port extender ID. Range is 0–255.
stack-unit
unit
number
Enter the keyword
stack-unit
and the stack unit number.
Range is 0–7.
Defaults
None
Command Modes
EXEC
Command History This guide is platform-specific. For command information about other platforms, refer
to the relevant
Dell Networking OS Command Line Reference Guide
.
The following is a list of the Dell Networking OS version history for this command.
Version
Description
9.9(0.0)
Introduced on the C9010.
Usage Information The
power inline suspend pe
command temporarily disables PoE power supply to
all the ports in a port extender (PE) unit. You can use the
power inline restore pe
command to restore or enable the PoE power supply to the PE unit.
Example
Dell#power inline suspend pe 1 stack-unit 2
% Error: StackUnit 2 of PE 1 not provisioned/connected
Port Extenders (PE)
1757
Summary of Contents for C9000 series
Page 1: ...Dell Networking Command Line Reference Guide for the C9000 Series Version 9 10 0 0 ...
Page 394: ...deny 14551 666 Dell Access Control Lists ACL 394 ...
Page 877: ...algorithm FIPS Cryptography 877 ...
Page 1297: ...Total 5 0 Total 5 active route s using 952 bytes IPv6 Basics 1297 ...