1.  Slide included and grommet strain relief boot 

onto cable.

2. Measure the tubing down the length of the 

cable. Place a mark 6”/15 cm from the end of 
the tubing.

3.  Using the fiber strippers’ 2.0 mm opening, 

remove the jacket at marking so that the  
exposed fiber is equal to the breakout tubing 
and assembly plus 6” or 15 cm.

4.  Working on a flat surface with an edge, tape 

down the cable.  

5.  Separate aramid yarns from fiber. Cut yarns 

approximately 6”/15 cm from end of jacket.

6.  Slide housing over exposed fibers.  For six 

fiber kit, place fibers 1-6 all on one side of 
housing.  If installing 12 fiber kit place fibers 
7-12 on other side. 

Cleerline SSF

TM

  3.0 mm Breakout Kit

This guide describes spider breakout kit installation on 250 µm optical fiber.  Installation factors such as available cable slack, 
location of the termination hardware and the question of build tube slack storage as opposed to cable slack can dictate when and 
where you choose to mount the cable end and assemble your breakout kit. 

Termination With: 

SSF

TM 

 Micro Distribution 250 µm Fibers

CLEERLINE

TECHNOLOGY GROUP

TM

cleerlinefiber.com

Revise #1.5

Each Breakout Kit Contains

a. Insert block furcation tube assembly

(1 for 6 fiber, 2 for 12 fiber)

b. Outer Shell
c. Housing
d. Grommet Strain Relief Boot
e. Nut
f.  Screw (x2)
g. Plug (not used in these instructions)
h. 6 Fiber Bushing (not used in these instructions)
i. 12 fiber Bushing (not used in these instructions)

 Required Tools

a. Fiber Optic Strippers
b. Aramid Shears
c. Pliers
d. Ruler
e. Tape
f. Marker