1. Slide included and grommet strain relief boot
onto cable.
2. Measure the tubing down the length of the
cable. Place a mark 6”/15 cm from the end of
the tubing.
3. Using the fiber strippers’ 2.0 mm opening,
remove the jacket at marking so that the
exposed fiber is equal to the breakout tubing
and assembly plus 6” or 15 cm.
4. Working on a flat surface with an edge, tape
down the cable.
5. Separate aramid yarns from fiber. Cut yarns
approximately 6”/15 cm from end of jacket.
6. Slide housing over exposed fibers. For six
fiber kit, place fibers 1-6 all on one side of
housing. If installing 12 fiber kit place fibers
7-12 on other side.
Cleerline SSF
TM
3.0 mm Breakout Kit
This guide describes spider breakout kit installation on 250 µm optical fiber. Installation factors such as available cable slack,
location of the termination hardware and the question of build tube slack storage as opposed to cable slack can dictate when and
where you choose to mount the cable end and assemble your breakout kit.
Termination With:
SSF
TM
Micro Distribution 250 µm Fibers
CLEERLINE
TECHNOLOGY GROUP
TM
cleerlinefiber.com
Revise #1.5
Each Breakout Kit Contains
a. Insert block furcation tube assembly
(1 for 6 fiber, 2 for 12 fiber)
b. Outer Shell
c. Housing
d. Grommet Strain Relief Boot
e. Nut
f. Screw (x2)
g. Plug (not used in these instructions)
h. 6 Fiber Bushing (not used in these instructions)
i. 12 fiber Bushing (not used in these instructions)
Required Tools
a. Fiber Optic Strippers
b. Aramid Shears
c. Pliers
d. Ruler
e. Tape
f. Marker