Message ID
Trap Type
Trap Option
%CHMGR-5-MINOR_PS_CLR: Minor alarm cleared: power
supply redundant
CHM_MIN_ALRM_TEMP
ENVMON
TEMP
%CHMGR-2-MINOR_TEMP: Minor alarm: chassis temperature
CHM_MIN_ALRM_TEMP_CLR
ENVMON
TEMP
%CHMRG-5-MINOR_TEMP_CLR: Minor alarm cleared: chassis
temperature normal (%s %d temperature is within
threshold of %dC)
CHM_MAJ_ALRM_TEMP
ENVMON
TEMP
%CHMGR-2-MAJOR_TEMP: Major alarm: chassis temperature
high (%s temperature reaches or exceeds threshold of
%dC)
CHM_MAJ_ALRM_TEMP_CLR
ENVMON
TEMP
%CHMGR-2-MAJOR_TEMP_CLR: Major alarm cleared: chassis
temperature lower (%s %d temperature is within
threshold of %dC)
CHM_FANTRAY_BAD
ENVMON
FAN
For E1200: %CHMGR-2-FAN_TRAY_BAD: Major alarm: fan
tray %d is missing or down
%CHMGR-2-ALL_FAN_BAD: Major alarm: all fans in fan
tray %d are down.
For E600 and E300: %CHMGR-2-FANTRAYBAD: Major alarm:
fan tray is missing
%CHMGR-2-FANSBAD: Major alarm: most or all fans in fan
tray are down
CHM_FANTRAY_BAD_CLR
ENVMON
FAN
For the E1200: %CHMGR-5-FAN_TRAY_OK: Major alarm
cleared: fan tray %d present
For the E600 and E300: %CHMGR-5-FANTRAYOK: Major alarm
cleared: fan tray present
CHM_MIN_FANBAD
ENVMON
FAN
For the E1200: %CHMGR-2-FAN_BAD: Minor alarm: some
fans in fan tray %d are down
For the E600 and E300: %CHMGR- 2-1FANBAD: Minor alarm:
fan in fan tray is down
CHM_MIN_FANBAD_CLR
ENVMON
FAN
For E1200: %CHMGR-2-FAN_OK: Minor alarm cleared: all
fans in fan tray %d are good
SNMP Traps
2103
Summary of Contents for C9000 series
Page 1: ...Dell Networking Command Line Reference Guide for the C9000 Series Version 9 10 0 0 ...
Page 394: ...deny 14551 666 Dell Access Control Lists ACL 394 ...
Page 877: ...algorithm FIPS Cryptography 877 ...
Page 1297: ...Total 5 0 Total 5 active route s using 952 bytes IPv6 Basics 1297 ...