Sep 8 13:07:30: %PE-UNKN-UNIT1-U:CP %RAM-6-ELECTION_ROLE: Stack-unit 1
is transitioning to Management Stack-unit.
Sep 8 13:07:31: %PE-UNKN-UNIT1-M:CP %CHMGR-5-STACKUNIT_DETECTED:
stack-unit 3 present
Sep 8 13:07:31: %PE-UNKN-UNIT1-M:CP %POLLMGR-2-ALT_STACKUNIT_STATE:
Alternate Stack-unit is present
Sep 8 13:07:31: %PE-UNKN-UNIT1-M:CP %CHMGR-5-STACKUNIT_DETECTED: stack-unit
1 present
Sep 8 13:07:31: %PE-UNKN-UNIT1-M:CP %CHMGR-5-CHECKIN: Checkin from
stack-unit 1 (type C1048P, 52 ports)
Sep 8 13:07:31: %PE-UNKN-C1048P:1 %CHMGR-2-FAN_SPEED_CHANGE: Fan speed
changed to 60 % of the full speed
Sep 8 13:07:31: %PE-UNKN-C1048P:1 %CHMGR-2-FAN_SPEED_CHANGE: Fan speed
changed to 75 % of the full speed
Sep 8 13:07:31: %PE-UNKN-UNIT1-M:CP %RAM-5-STACKUNIT_STATE: Stack-unit 1
is in Active State.
Sep 8 13:07:32: %PE-UNKN-UNIT1-M:CP %IFMGR-5-ASTATE_UP: Changed interface
Admin state to up: Po 257
Sep 8 13:07:32: %PE-UNKN-UNIT1-M:CP %CHMGR-5-PEM_INSERTED: Power entry
module 0 of unit 1 is inserted
Sep 8 13:07:32: %PE-UNKN-UNIT1-M:CP %CHMGR-0-PS_UP: Power supply 0 in
unit 1 is up
Sep 8 13:07:32: %PE-UNKN-UNIT1-M:CP %CHMGR-5-PEM_REMOVED: Power entry
module 1 of unit 1 is absent
Sep 8 13:07:32: %PE-UNKN-UNIT1-M:CP %CHMGR-5-FANTRAY_INSERTED: Fan tray 0
of Unit 1 is inserted
Sep 8 13:07:32: %PE-UNKN-UNIT1-M:CP %CHMGR-4-TEMP_STATUS_CHANGE: Unit 1
temperature state changed
to 1 (Current temperature 40C).
Sep 8 13:07:32: %PE-UNKN-UNIT1-M:CP %SEC-5-LOGIN_SUCCESS: Login successful
on console
Sep 8 13:07:32: %PE-UNKN-UNIT1-M:CP %IFMGR-5-ASTATE_UP: Changed interface
Admin state to up: Te 1/1
Sep 8 13:07:33: %PE-UNKN-UNIT1-M:CP %IFMGR-5-ASTATE_UP: Changed interface
Admin state to up: Te 1/2
Sep 8 13:07:33: %PE-UNKN-C1048P:1 %IFAGT-5-STACK_PORT_LINK_UP: Changed
stack port state to up: 1/1
Sep 8 13:07:33: %PE-UNKN-C1048P:1 %IFAGT-5-INSERT_OPTICS_PLUS: Optics SFP+
inserted in slot 1 port 1
Sep 8 13:07:33: %PE-UNKN-UNIT1-M:CP %CHMGR-5-STACKUNIT_UP: stack-unit 1
is up
Sep 8 13:07:33: %PE-UNKN-UNIT1-M:CP %CHMGR-5-CHECKIN: Checkin from
stack-unit 3 (type C1048P, 52 ports)
Sep 8 13:07:33: %PE-UNKN-UNIT1-M:CP %IFMGR-5-ASTATE_UP: Changed interface
Admin state to up: Te 3/1
Sep 8 13:07:33: %PE-UNKN-UNIT1-M:CP %IFMGR-5-ASTATE_UP: Changed interface
Admin state to up: Te 3/2
Sep 8 13:07:33: %PE-UNKN-UNIT1-M:CP %CHMGR-5-STACKUNIT_UP: stack-unit3 is up
Sep 8 13:07:33: %PE-UNKN-UNIT1-M:CP %CHMGR-2-SYSTEM_READY: System ready
Sep 8 13:07:34: %PE-UNKN-UNIT1-M:CP %CHMGR-5-PEM_INSERTED: Power entry
module 0 of unit 3 is inserted
Sep 8 13:07:34: %PE-UNKN-UNIT1-M:CP %CHMGR-0-PS_UP: Power supply 0 in unit
3 is up
Sep 8 13:07:34: %PE-UNKN-UNIT1-M:CP %CHMGR-5-PEM_INSERTED: Power entry
module 1 of unit 3 is inserted
Sep 8 13:07:34: %PE-UNKN-UNIT1-M:CP %CHMGR-0-PS_DOWN: Major alarm: Power
supply 1 in unit 3 is down
Sep 8 13:07:34: %PE-UNKN-C1048P:3 %CHMGR-2-FAN_SPEED_CHANGE: Fan speed
changed to 60 % of the full speed
Sep 8 13:07:34: %PE-UNKN-UNIT1-M:CP %CHMGR-5-FANTRAY_INSERTED: Fan tray 0
of Unit 3 is inserted
Sep 8 13:07:34: %PE-UNKN-C1048P:3 %CHMGR-2-FAN_SPEED_CHANGE: Fan speed
changed to 60 % of the full speed
Sep 8 13:07:34: %PE-UNKN-C1048P:3 %CHMGR-2-FAN_SPEED_CHANGE: Fan speed
changed to 75 % of the full speed
Sep 8 13:07:35: %PE-UNKN-UNIT1-M:CP %CHMGR-4-TEMP_STATUS_CHANGE: Unit 3
temperature state changed
o 1 (Current temperature 44C).
Sep 8 13:07:35: %PE-UNKN-C1048P:3 %IFAGT-5-STACK_PORT_LINK_UP: Changed stack
port state to up: 3/1
Sep 8 13:07:35: %PE-UNKN-C1048P:3 %IFAGT-5-INSERT_OPTICS_PLUS: Optics SFP+
Control and Monitoring
180
Summary of Contents for C9000 series
Page 1: ...Dell Networking Command Line Reference Guide for the C9000 Series Version 9 10 0 0 ...
Page 394: ...deny 14551 666 Dell Access Control Lists ACL 394 ...
Page 877: ...algorithm FIPS Cryptography 877 ...
Page 1297: ...Total 5 0 Total 5 active route s using 952 bytes IPv6 Basics 1297 ...