owner
name
(OPTIONAL) Enter the keyword
owner
then the owner name to
record the owner of the RMON group of statistics.
buckets
number
(OPTIONAL) Enter the keyword
buckets
then the number of
buckets for the RMON collection history group of statistics. The
bucket range is from 1 to 1000. The default is
50
.
interval
seconds
(OPTIONAL) Enter the keyword
interval
then the number of
seconds in each polling cycle. The range is from 5 to 3600
seconds. The default is
1800 seconds
.
Defaults
none
Command Modes
CONFIGURATION INTERFACE (config-if)
Command History This guide is platform-specific. For command information about other platforms, refer
to the relevant
Dell Networking OS Command Line Reference Guide
.
The following is a list of the Dell Networking OS version history for this command.
Version
Description
9.9(0.0)
Introduced on the C9010.
9.2(1.0)
Introduced on the Z9500.
8.3.19.0
Introduced on the S4820T.
8.3.11.1
Introduced on the Z9000.
8.3.7.0
Introduced on the S4810.
7.6.1.0
Introduced on the S-Series.
7.5.1.0
Introduced on the C-Series.
6.1.1.0
Introduced on the E-Series.
rmon collection statistics
Enable RMON MIB statistics collection on an interface.
C9000 Series
Syntax
rmon collection statistics {controlEntry
integer
} [owner
name
]
To remove RMON MIB statistics collection on an interface, use the
no rmon
collection statistics {controlEntry
integer
}
command.
Remote Monitoring (RMON)