Addr.
Parameter
C
Setting Options
Default Setting
_:8881:127
CT 3-phase:Tracking
•
inactive
•
active
active
_:8881:130
CT 3-phase:Measuring-
point ID
0 to 100
0
CT phases
_:8881:101
CT 3-phase:Rated primary
current
1.0 A to 100000.0 A
1000.0 A
_:8881:102
CT 3-phase:Rated secon-
dary current
•
1 A
•
5 A
1 A
_:8881:117
CT 3-phase:Current range
•
1.6 x IR
•
8 x IR
•
20 x IR
•
100 x IR
100 x IR
_:8881:118
CT 3-phase:Internal CT type
•
CT protection
•
CT measurement
CT protection
_:8881:116
CT 3-phase:Neutr.point in
dir.of ref.obj
•
no
•
yes
yes
_:8881:114
CT 3-phase:Inverted phases
•
none
•
AC
•
BC
•
AB
none
_:8881:107
CT 3-phase:CT error
changeover
1.00 to 10.00
1.00
_:8881:108
CT 3-phase:CT error A
0.5 % to 50.0 %
5.0 %
_:8881:109
CT 3-phase:CT error B
0.5 % to 50.0 %
15.0 %
CT IN
_:8881:104
CT 3-phase:Rated primary
current
1.0 A to 100000.0 A
1000.0 A
_:8881:105
CT 3-phase:Rated secon-
dary current
•
1 A
•
5 A
1 A
_:8881:119
CT 3-phase:Current range
•
1.6 x IR
•
8 x IR
•
20 x IR
•
100 x IR
100 x IR
_:8881:120
CT 3-phase:Internal CT type
•
CT protection
•
CT measurement
CT protection
CT IN2
_:8881:106
CT 3-phase:Rated primary
current
1.0 A to 100000.0 A
1000.0 A
_:8881:113
CT 3-phase:Rated secon-
dary current
1 A to 5 A
1 A
_:8881:121
CT 3-phase:Current range
•
1.6 x IR
•
8 x IR
•
20 x IR
•
100 x IR
1.6 x IR
_:8881:122
CT 3-phase:Internal CT type
•
CT protection
•
CT measurement
CT protection
CT 1
_:3841:103
CT 1:Magnitude correction
0.010 to 10.000
1.000
Function-Group Types
5.1 Power-System Data
190
SIPROTEC 5, High-Voltage Bay Controller, Manual
C53000-G5040-C015-9, Edition 11.2017
Summary of Contents for 6MD85
Page 8: ...8 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 30: ...30 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 46: ...46 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 172: ...172 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 514: ...514 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 1056: ...1056 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 1092: ...1092 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 1204: ...1204 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 1238: ...1238 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 1252: ...1252 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 1256: ...1256 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...