Addr.
Parameter
C
Setting Options
Default Setting
_:781:41
Inverse-T 1:Stage
blocked
•
no
•
yes
no
_:781:19
Inverse-T 1:Threshold
1 A @ 100 Irated 0.010 A to 35.000 A
1.200 A
5 A @ 100 Irated 0.05 A to 175.00 A
6.00 A
1 A @ 50 Irated
0.010 A to 35.000 A
1.200 A
5 A @ 50 Irated
0.05 A to 175.00 A
6.00 A
1 A @ 1.6 Irated
0.001 A to 1.600 A
1.200 A
5 A @ 1.6 Irated
0.002 A to 8.000 A
6.000 A
_:781:107
Inverse-T 1:Time dial
0.00 to 15.00
1.00
Information List
No.
Information
Data Class
(Type)
Type
General
_:2311:500
General:>Activation emg. mode
SPS
I
_:2311:300
General:Emergency mode act.
SPS
O
Group indicat.
_:4501:55
Group indicat.:Pickup
ACD
O
_:4501:57
Group indicat.:Operate
ACT
O
Inverse-T 1
_:781:81
Inverse-T 1:>Block stage
SPS
I
_:781:84
Inverse-T 1:>Activ. dyn. settings
SPS
I
_:781:500
Inverse-T 1:>Block delay & op.
SPS
I
_:781:54
Inverse-T 1:Inactive
SPS
O
_:781:52
Inverse-T 1:Behavior
ENS
O
_:781:53
Inverse-T 1:Health
ENS
O
_:781:60
Inverse-T 1:Inrush blocks operate
ACT
O
_:781:62
Inverse-T 1:Dyn.set. AR cycle1act.
SPS
O
_:781:63
Inverse-T 1:Dyn.set. AR cycle2act.
SPS
O
_:781:64
Inverse-T 1:Dyn.set. AR cycle3act.
SPS
O
_:781:65
Inverse-T 1:Dyn.set. ARcycl.>3act
SPS
O
_:781:66
Inverse-T 1:Dyn.set. CLP active
SPS
O
_:781:67
Inverse-T 1:Dyn.set. BI active
SPS
O
_:781:68
Inverse-T 1:Dyn. set. blks. pickup
SPS
O
_:781:59
Inverse-T 1:Disk emulation running
SPS
O
_:781:55
Inverse-T 1:Pickup
ACD
O
_:781:56
Inverse-T 1:Operate delay expired
ACT
O
_:781:57
Inverse-T 1:Operate
ACT
O
Stage with User-Defined Characteristic Curve
Description
This stage is only available in the advanced function type.
This stage is structured the same way as the Inverse-time overcurrent protection – advanced stage (see
chapter
). The only differences are as follows:
7.5.5.4
7.5.6
7.5.6.1
Protection and Automation Functions
7.5 Overcurrent Protection, Ground
SIPROTEC 5, High-Voltage Bay Controller, Manual
655
C53000-G5040-C015-9, Edition 11.2017
Summary of Contents for 6MD85
Page 8: ...8 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 30: ...30 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 46: ...46 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 172: ...172 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 514: ...514 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 1056: ...1056 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 1092: ...1092 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 1204: ...1204 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 1238: ...1238 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 1252: ...1252 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 1256: ...1256 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...