Pulse- and Energy- Metered Values
Pulse-Metered Values
Pulse-metered values are available as data types BCR (Binary Counter Reading) in the DIGSI library under User-
defined Functions.
The functionality and the settings of the pulse-metered values can be found in chapter
Description of Pulse-Metered Values
.
Energy-Metered Values
Energy-metered values no longer need to be created by the user separately. They are available as active and
reactive power in each Line function group for reference and output direction. The calculation is based on the
current and voltage transformers associated with the protected object.
You can find more detailed information in chapter
9.9.1 Function Description of Energy Values
.
Additional Data Types
The following data types are also used in the system but are not available for general use as user-defined
signals in the library:
•
ENC (Enumerated Setting Controllable)
The data type ENC models a command with which the user can set predefined values.
•
SEQ (Sequence)
•
BSC (Binary Controlled Step Position)
The data type BSC can, for example, be used to control a transformer tap changer. The commands up,
down can be given.
i
i
NOTE
Transformer taps are included in the Transformer tap changer switching element. If this switching
element is created in the device, the transformer tap position is available as a data object of type BSC
(binary controlled step position information).
External Signals
User-defined signals of different types (see
) are available for GOOSE Later Binding. After instantia-
tion in a logical node, an external reference is generated during IID export and provided to a IEC 61850 system
tool (for example, System Configurator) for GOOSE Later Binding (according to the Later-Binding procedure
specified in IEC 61850-6).
3.7.3
3.7.4
3.7.5
System Functions
3.7 User-Defined Objects
SIPROTEC 5, High-Voltage Bay Controller, Manual
141
C53000-G5040-C015-9, Edition 11.2017
Summary of Contents for 6MD85
Page 8: ...8 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 30: ...30 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 46: ...46 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 172: ...172 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 514: ...514 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 1056: ...1056 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 1092: ...1092 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 1204: ...1204 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 1238: ...1238 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 1252: ...1252 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 1256: ...1256 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...