Protection Device
A protection device detects fault states in distribution networks, taking into account various criteria, such as
fault distance, fault direction or fault duration, triggering a disconnection of the defective network section.
Protocol Implementation Conformance Statement
The performance properties of the system to be tested are summarized in the report on the conformity of
implementation of a protocol (PICS = Protocol Implementation Conformance Statement).
PRP
See Parallel Redundancy Protocol
Rapid Spanning Tree Protocol
The Rapid Spanning Tree Protocol (RSTP) is a standardized redundancy process with a short response time. In
the Spanning Tree Protocol (STP protocol), structuring times in the multidigit second range apply in the case of
a reorganization of the network structure. These times are reduced to several 100 milliseconds for RSTP.
Real Time
Real time
Reorganize
The frequent addition and deletion of objects results in memory areas which are no longer used. The reorgani-
zation of projects allows these memory areas to be freed up again. The reorganization also leads to VD
addresses being reassigned. This results in all SIPROTEC devices having to be reinitialized.
RSTP
See Rapid Spanning Tree Protocol.
SBO
Select before operate
SC
Single command – See Single Command.
SCD
See Substation Configuration Description
Sequence of Events
Acronym: SOE. An ordered, time-stamped log of status changes at binary inputs (also referred to as state
inputs). SOE is used to restore or analyze the performance, or an electrical power system itself, over a certain
period of time.
Service Interface
Device interface for interfacing DIGSI 5 (for example, through a modem)
SI
See Single-Point Indication.
SI
See System Interface.
Glossary
1248
SIPROTEC 5, High-Voltage Bay Controller, Manual
C53000-G5040-C015-9, Edition 11.2017
Summary of Contents for 6MD85
Page 8: ...8 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 30: ...30 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 46: ...46 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 172: ...172 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 514: ...514 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 1056: ...1056 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 1092: ...1092 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 1204: ...1204 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 1238: ...1238 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 1252: ...1252 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...
Page 1256: ...1256 SIPROTEC 5 High Voltage Bay Controller Manual C53000 G5040 C015 9 Edition 11 2017 ...