Foundry NetIron M2404C and M2404F Metro Access Switches
Network Administration Tools (Rev. 03)
802.1ag Connectivity Fault Management (CFM)
© 2008 Foundry Networks, Inc.
Page 114 of 155
Sent 10. Received 10. Success rate 100%
Time msec. (min/avg/max): 0/1/5
Send a linktrace message to a specified MEP in a specified domain
Device1
#
cfm linktrace domain d7 ma ma7 mep 1 target-mep 2
Tracing link from 1 to mep-id 2 (00:12:F2:11:02:22)
Sending loopback message to refresh MAC address tables...
Loopback reply received
Sending Linktrace Message
Waiting to receive Linktrace Replies
Reply with ttl 63 transID 7684 from 00:12:F2:11:02:22 (5 ms)
Done.
Linktrace statistics :
>TTL 63 :Foundry : MAC 00:12:F2:11:02:22 (0.005s)
Using the
clear connectivity
Command
This example is based on the following figure (
Figure 20
) and describes the using of the
clear
connectivity
command.
Figure 20: Example for Using the clear connectivity Command
Configuring Device1:
1. Create a VLAN with the specified name
vl10
and ID
10
.
Device1
#
configure terminal
Device1
(config)#
vlan
Device1
(config vlan)#
create vl10 10
2. Change the configuration mode to a specified VLAN configuration mode
specified by name in the command argument.