Foundry NetIron M2404C and M2404F Metro Access Switches
Troubleshooting and Monitoring (Rev. 03)
Periodic Monitoring
© 2008 Foundry Networks, Inc.
Page 35 of 55
Setting LED Alert Notifications for a Specific Indicator
The
status-led
command, in Monitoring Configuration mode, enables LED alert notification for
the configured indicator.
If status-led alerts are enabled, the status LED on the unit will blink when:
•
the indicator status is Fail
-
or
-
•
the indicator measured value exceeds its configured limit
-
or
-
•
the indicator measured value crosses a configured delta point.
By default, the LED alert is enabled.
Command Syntax
device-name
(config monitor
INDICATOR
)#
status-led
{
enable
|
disable
}
Argument Description
enable
Enables or activates monitoring alerts.
disable
Disables or deactivates monitoring alerts.
Examples
This example disables the unit status LED for fans:
device-name
(config monitor fan)#
status-led disable
Setting Trap Alert Notifications for a Specific Indicator
The
trap
command, in Monitoring Configuration mode, enables SNMP trap alert notification for
the configured indicator.
If trap alerts are enabled, an SNMP trap is issued when:
•
the indicator status is Fail
-
or
-
•
the indicator measured value exceeds its configured limit
-
or
-
•
the indicator measured value crosses a configured delta point.
To use the trap option, see chapter “
Configuring Simple Network Management Protocol (SNMP)
”.
By default, the trap alert is enabled.
Command Syntax
device-name
(config monitor
INDICATOR
)#
trap
{
enable
|
disable
}
Argument Description
enable
Enables the monitoring alerts.