Foundry NetIron M2404C and M2404F Metro Access Switches
Network Administration Tools (Rev. 03)
802.1ag Connectivity Fault Management (CFM)
© 2008 Foundry Networks, Inc.
Page 112 of 155
Device1
(config vlan)#
config vl10
3. Add port 1/1/1 as a tagged port.
Device1
(config-vlan vl10)#
add ports 1/1/1 tagged
Device1
(config-vlan vl10)#
end
4. Enable the CFM protocol.
Device1
#
configure terminal
Device1
(config)#
cfm enable
5. Create a maintenance domain with a specified name
d7
and level
7
and create
a maintenance association within a specified domain.
Device1
(config-cfm)#
domain name d7 level 7
Device1
(config-cfm-d7)#
ma name ma7 vlan-ID 10
6. Specify the identification data sent to the remote MEPs creation policy on the specified MA:
Device1
(config-cfm
-
d7-ma7)#
senderid-content hostname
Device1
(config-cfm
-
d7-ma7
)
#
mip-policy explicit
6. Add port 1/1/1 as MEP to a specified maintenance association.
Device1
(config-cfm-d7-ma7)#
mep 1 port 1/1/1 out
Device1
(config-cfm-d7-ma7)#
end
Configuring Device2:
1. Create VLAN with the specified name
vl10
and ID
10
.
Device2
#
configure terminal
Device2
(config)#
vlan
Device2
(config vlan)#
create vl10 10
2. Change the configuration mode to a specified VLAN configuration mode
specified by name in the command argument.
Device2
(config vlan)#
config vl10
3. Add port 1/1/2 as a tagged port.
Device2
(config-vlan vl10)#
add ports 1/1/2 tagged
Device2
(config-vlan vl10)#
end
4. Enable the CFM protocol.
Device2
#
configure terminal
Device2
(config)#
cfm enable
5. Create a maintenance domain with a specified name
d7
and level
7
and create
a maintenance association within a specified domain.
Device2
(config-cfm)#
domain name d7 level 7
Device2
(config-cfm-d7)#
ma name ma7 vlan-ID 10