Foundry NetIron M2404C and M2404F Metro Access Switches
Network Administration Tools (Rev. 03)
Response Time Reporter (RTR)
© 2008 Foundry Networks, Inc.
Page 129 of 155
Argument Description
number
Content of data field in hexadecimal numbers with format up to 1024 octets.
Setting the Data Size
The
data-size
command, in RTR Configuration mode, sets the size of the data field of test probes.
The
no
form of this command resets the data size to default.
By default, the data size of the probes is 0.
Command Syntax
device-name
(config-rtr)#
data-size <number>
device-name
(config-rtr)#
no
data-size
Argument Description
number
Size of data field in the range of <0-65507> for tcpecho test and <0-64283> for all
other types.
Setting the Frequency
The
frequency
command, in RTR Configuration mode, sets the time period at which the operation
should send out probes to gather statistics. The
no
form of this command resets the time period to
its default value
This command applies to all operation types.
By default there is no repetition (the value 0).
Command Syntax
device-name
(config-rtr)#
frequency <number>
device-name
(config-rtr)#
no frequency
Argument Description
number
Test repetition interval in seconds. The range is <0-65535> seconds. The value
specifies the number of seconds waited from the completion of a test run to the
initiation the next test run. The value 0 defines the test as non-repetitive
Setting the Number of Probes
The
probe-count
command, in RTR Configuration mode, sets the number of probes in a test. The
no
form of this command resets the probe count to its default value.
By default, the number of probes in a test is 1.
Command Syntax
device-name
(config-rtr)#
probe-count <number>
device-name
(config-rtr)#
no
probe-count