Foundry NetIron M2404C and M2404F Metro Access Switches
Troubleshooting and Monitoring (Rev. 03)
Periodic Monitoring
© 2008 Foundry Networks, Inc.
Page 28 of 55
Table 13: Periodic Monitoring Default Parameter Values
Parameter
Default Value
Temperature monitoring
Enabled
Temperature monitoring scale
Celsius
Fan monitoring
Enabled
Power supply monitoring
Enabled
CPU usage
Enabled
RAM (memory) usage
Enabled
Log message alert
Enabled
Led alert
Enabled
Trap alert
Enabled
Limit values for monitoring alert
See
Table 14
Delta value for monitoring alert
Disabled
Monitoring period
See
Table 15
Table 14: Limit Values for Monitoring Alert Default Parameter Values
Parameter
Default Value
Limit value for temperature monitoring alert
55
°
C / 131
°
F
Limit value for CPU usage monitoring alert
75%
Limit value for RAM usage monitoring alert
1000Kbytes
Table 15: Monitoring Period Default Values
Parameter
Default Value
Monitoring period for fan
60 seconds
Monitoring period for power supply
60 seconds
Monitoring period for temperature
20 seconds
Monitoring period for CPU usage
10 seconds
Monitoring period for RAM usage
30 seconds
Configuring and Displaying Periodic Monitoring
To set periodic monitoring for one of the indicators, proceed as follows:
1.
Enable monitoring of the indicator if it is not enabled by default. There are two ways to enable
(or disable) periodic monitoring of one of the indicators: