Foundry NetIron M2404C and M2404F Metro Access Switches
Network Administration Tools (Rev. 03)
MEF OAM
© 2008 Foundry Networks, Inc.
Page 29 of 155
Command Syntax
device-name
(config-oam LEVEL)#
oam create-process HH:HH:HH:HH:HH:HH
[
NAME
]
[
repeat minutes
<minutes>
[
seconds
<seconds>
]]
Argument Description
HH:HH:HH:HH:HH:HH
Destination MAC Address for two-way connectivity test.
NAME
(Optional). Name of the monitoring process (text). The length
of the name is limited to 19 characters (only the first 19
characters will be accepted). If this parameter is not specified,
the test name is defined as the destination MAC address of this
test.
repeat minutes <minutes>
seconds <seconds>
(Optional). Repetition interval of the monitoring process in the
range <0-60>min and/or <0-60>seconds.
Configuring an OAM Two-way Monitoring Process
The
oam process
command, in MEF OAM Configuration mode, enters into predefined OAM
Process Configuration mode. The
no
form of this command removes the OAM process.
By default, the process name is the remote monitored device MAC address.
Command Syntax
device-name
(config-oam
LEVEL
)#
oam process
NAME
device-name
(config-oam
LEVEL
)#
no
oam process
NAME
Argument Description
NAME
Name of the monitoring process (text).
Setting the VLAN ID
The
oam vlan
command, in OAM Process Configuration mode, sets the VLAN ID to use for the
specified two-way monitoring process. The
no
form of this command restores the default setting.
By default, the connectivity test requests are sent through all the VLANs defined in the MEF OAM
domain.
Command Syntax
device-name
(config-oam
LEVEL-NAME
)#
oam vlan <vlan-id>
device-name
(config-oam
LEVEL-NAME
)#
no oam vlan
Argument Description
vlan-id
VLAN ID to use for subsequent connectivity test, in the range <1-4093>.