Foundry NetIron M2404C and M2404F Metro Access Switches
Appendix A: Default Configuration (Rev. 01)
Default Configuration
© 2008 Foundry Networks, Inc
Page 24 of 38
Periodic Monitoring Default Configuration
Table 48
shows the periodic monitoring default configuration.
Table 48: Periodic Monitoring Default Configuration
Parameter
Default Value
Temperature monitoring
Enabled
Temperature monitoring scale
Celsius
Fan monitoring
Enabled
Power supply monitoring
Enabled
CPU usage
Enabled
RAM (memory) usage
Enabled
Log message alert
Enabled
Led alert
Enabled
Trap alert
Enabled
Limit values for monitoring alert
See
Table 49
Delta value for monitoring alert
Disabled
Monitoring period
See
Table 50
Table 49: Limit Values for Monitoring Alert Default Configuration
Parameter
Default Value
Limit value for temperature monitoring alert
55
°
C / 131
°
F
Limit value for CPU usage monitoring alert
75%
Limit value for RAM usage monitoring alert
1000Kbytes
Table 50: Monitoring Period Default Configuration
Parameter
Default Value
Monitoring period for fan
60 seconds
Monitoring period for power supply
60 seconds
Monitoring period for temperature
20 seconds
Monitoring period for CPU usage
10 seconds
Monitoring period for RAM usage
30 seconds
Port Security Default Configuration
Table 51
shows the port security default configuration.