Foundry NetIron M2404C and M2404F Metro Access Switches Configuring VLANs (Rev.03)
Super VLANs
© 2008 Foundry Networks, Inc.
Page 53 of 73
Command Syntax
device-name
(config-if
UU/SS/PP
)#
super-vlan ring-topology
{
UU1/SS1/PP1
|
agNN1
}
{
UU2/SS2/PP2
|
agNN2
} [
vlan <vlan-id>
]
device-name
(config-if
UU/SS/PP
)#
no super-vlan
Argument Description
UU1/SS1/PP1
First ring-port of the super VLAN.
UU2/SS2/PP2
Second ring-port of the super VLAN.
agNN1
First Link aggregation interface name, where
NN1
represents the LAG ID
number. For detailed information, see chapter
“Configuring Link
Aggregation Groups (LAG)”.
agNN2
Second Link aggregation interface name, where
. NN2
represents the LAG
ID number. For detailed information, see chapter
“Configuring Link
Aggregation Groups (LAG)”.
vlan <vlan-id>
(Optional).
Specifies the VLAN ID number, in the range <2-4093. When
configured, only the corresponding MSTP instance root-decision is taken. If
not set, only MSTP instance Zero-root port updates the Super VLAN ring
mode.
Super VLAN Display Commands
Table 12
lists the Super VLAN display command.
Table 12: Super VLAN Display Command
Command
Description
show super-vlan
Displays the Super VLAN configuration.
Displaying the Super VLAN Configuration
The
show
super-vlan
command, in Privileged (Enable) mode, displays the Super VLAN
configuration.
Command Syntax
device-name
#
show
super-vlan
Example
device-name
#
show
super-vlan
==================================================
User Interface | Super VLAN Type | Uplink
-----------------+-----------------+--------------
1/1/1 | regular | 1/1/2
1/1/5 | ring-topology | 1/1/6 (active), 1/1/7