Foundry NetIron M2404C and M2404F Metro Access Switches
Network Administration Tools (Rev. 03)
Intermediate 802.3ah EFM OAM
© 2008 Foundry Networks, Inc.
Page 73 of 155
no-remote-
loopback
(Optional). Do not set remote loopback for this operation. Remote loopback
has been set manually.
Note that on the local interface the remote loopback is set in loopback on its
state.
timeout
<
timeout
>
(Optional). Wait for response in seconds in the range <1-600> (default
value is 2 seconds).
NOTE
When the remote interface is involved in loopback, regardless the usage or no-
usage of the
no-remote-loopback
option, the operation is performed.
Example
device-name
#
efm-oam loopback 1/1/2 storm count 4 delay 3 packet-size 1510
timeout 10
Setting Loopback ..... Started ..... Completed
Generating Test Traffic ..... Started ..... Completed
Stopping loopback ..... Started ..... Completed
Sent: 3 packets / 4530 octets
Received Successfully: 1 packets / 1510 octets
Local Remote
InOctets 182078 InOctets 127025
OutOctets 173909 OutOctets 119198
InUcastPkts 734 InUcastPkts 639
InNUcastPkts 1684 InNUcastPkts 894
OutUcastPkts 638
OutNUcastPkts 1628
InDiscards 0
OutDiscards 0
InErrors 0
OutErrors 0
Enabling EFM-OAM Get Variable
The
efm-oam
get
command, in Privileged (Enable) mode, enables the EFM-OAM get variable
operations for interface specific counters.
When the remote device is in enhanced EFM-OAM mode, it is possible to retrieve any SNMP
variable.
When the general SNMP parameter is required and the remote device does not use the enhanced
EFM-OAM mode, the “% Device connected to port 1 is not using enhanced mode” error message
will be displayed.
When the command is used with no parameters, it displays parameters identical with these
displayed by the “
show efm-oam
UU/SS/PP
statistics”
command.
NOTE
Currently Get Variable SNMP is not implemented.