Foundry NetIron M2404C and M2404F Metro Access Switches
Troubleshooting and Monitoring (Rev. 03)
Built-in Self Test (BiST)
© 2008 Foundry Networks, Inc.
Page 6 of 55
Data Buffer Test :
Application Image Validity - Passed
Java Agent Image Validity - Passed
PROM Device Access Validity - Passed
Power Supply Test :
Power Supply 1 - Not installed
Power Supply Fan 1 - Passed
Power Supply 2 - Passed
Power Supply Fan 2 - Not installed
On-board Power Test :
On-board Power 3.3V - Passed
On-board Power 2.5V - Passed
On-board Power 1.8V - Passed
On-board Power 1.25V - Passed
Fan Test :
Fan 1 - Failed
Fan 2 - Failed
Fan 3 - Failed
Temperature Test :
Temperature - Passed
Displaying the Self Test Results
The
show self-test
command, in Privileged (Enable) mode, issues a report on the current built-in
test status (generated by the previous BiST).
If the argument
full
is not specified, the command issues a brief report, comprising:
•
A notification stating whether problems were encountered.
•
Items that failed (if any), with their (
Failed
) statuses.
Command Syntax
device-name
#
show self-test
[
full
]
Argument Description
full
(Optional). The command issues a full report, comprising the status
(
Passed
/
Failed
) of each test.
Example 1
The following example displays a brief report about the current BiST status, when all tests resulted
in a
Passed
status:
device-name
#
show self-test
no problem encountered by bist
Example 2
The following example displays a brief report about the current BiST status, when the Fan tests
resulted in a
Failed
status: