![Omron CS1W-MCH71 - Скачать руководство пользователя страница 695](http://html1.mh-extra.com/html/omron/cs1w-mch71/cs1w-mch71_operation-manual_742367695.webp)
650
Axis-related Alarm Codes
Section 11-6
Command
timeout
037Ah
-
0399h
300Ch
300Ch
A MECHATROLINK command could not be
completed within a fixed period of time (10
seconds). The followings are the possible
causes:
• Disconnection, breakage of MECHA-
TROLINK cable
Check the MECHATROLINK cable.
• Communications error caused by noise
Remove the cause of the noise.
When this error persists even after provid-
ing these remedies, the Driver (NS115) or
MC Unit may be broken. Replace the bro-
ken one with a new unit.
Any time
Servo OFF Enabled
Absolute
encoder error
300Dh
300Dh
Data from the ABS encoder could not be
processed normally.
• Initial multi-turn value exceeds the multi-
turn limit.
Set the same value in the driver parame-
ter [Pn205: Multi-turn limit setting] and the
motor parameter [900C: Multi-turn limit].
After the setting is completed, restore the
power, reset the alarm, and perform the
origin setting.
• After origin setting, the following values
related to B/A were changed.
Note
B = No. of encoder pulses
×
P5AA05
A = P5AA04
×
P5AA06
B/A is integer calculation and the
result is to be reduced.
After the change was made (saving
to F-ROM), restore the power, reset
the alarm, and perform origin setting.
• The multi-turn limit value in the driver
parameter or the motor parameter was
changed after origin setting.
After the change was made (saving to F-
ROM), restore the power, reset the alarm,
and perform origin setting. (When the
multi-turn value of the driver parameter
was changed, make sure to perform
“Absolute encoder multi-turn amount set-
ting change” on the driver.)
• Servo driver is set as an incremental
encoder. Set the driver parameter Pn002
digit No. 2 to “0” (used as an absolute
encoder) and restore the power.
• Disconnection, breakage of encoder
cable
Check the encoder cable.
• Communications error caused by noise
Remove the cause of the noise.
When this error persists even after provid-
ing these remedies, the encoder or MC
Unit may be broken. Replace the broken
one with a new unit.
When
synchro-
nous
commu-
nications
starts
Servo OFF Enabled
Name
Error log
Alarm
code
Cause and remedy
Timing
Rank
Reset
Error
code
Detail
code
Содержание CS1W-MCH71 -
Страница 2: ...CS1W MCH71 CJ1W MCH71 Motion Control Unit Operation Manual Revised June 2008 ...
Страница 3: ...iv ...
Страница 29: ...xxx ...
Страница 33: ...xxxiv ...
Страница 35: ...xxxvi ...
Страница 39: ...xl ...
Страница 69: ...24 Performance Section 1 7 ...
Страница 99: ...54 Connecting MECHATROLINK Devices Section 3 5 ...
Страница 283: ...238 Saving Data Section 5 4 ...
Страница 417: ...372 Command Details Section 6 3 ...