Allocations for the CPU Unit
Section 7-3
03: DM area (custom address)
Specifies DM area of PLC starting from the specified first address
(m+3).
04: EM area (custom word)
Specifies EM area of PLC starting from the specified first address
(m+3).
When EM area (04) is specified for the operation data area in area type
specification (word m+2), EM area is fixed at Bank No.0.
Note
Do not set the bank No. of the file memory on PLC. Specifying EM area of the
file memory bank No. causes the alarm [0044h: CPU memory error].
When mounting several MC Units on the same PLC, make sure that operation
data areas do not overlap. Since MC Units do not detect the error even if cus-
tom data areas of different Units are overlapping in PLC, a malfunction may
result.
For details on bank and file memory for the EM Area, refer to the
SYSMAC
CS Series Programmable Controllers Operation Manual
(W339) or the
SYS-
MAC CJ Series Programmable Controllers Operation Manual
(W393).
• First address (word m+3)
When CIO (0001), WR (0002), DM (0003), or EM area (0004) is specified
for the operation data area in the area type specification (word m+2), the
first address is to be specified.
Set the first address in hexadecimal (Hex). The setting ranges are as fol-
lows:
CIO area: 0000 to 177F Hex (0 to 6015)
WR area: 0000 to 017F Hex (0 to 383)
DM area: 0000 to 7F7F Hex (0 to 32639)
EM area: 0000 to 7F7F Hex (0 to 32639)
When “Does not use the custom data area (0000)” is specified in the area
type specification (word m+2), this setting is not necessary.
Setting example
The custom data area is allocated, as shown below, starting from word
7530Hex (30000) of DM area in PLC.
Note
Custom data area is allocated for 32 axes starting from the specified first
address regardless of the setting of the axis parameter [P1AA01: Physical
axis setting].
However, in the addresses corresponding to the axes that are set to “Not
used” in the axis parameter [P1AA01: Physical axis setting], data is not trans-
ferred between CPU Unit and MC Unit.
m+2
0003
m+3
7530
30000
30032 to 30034
30001
30035 to 30037
30030
30122 to 30124
30031
30125 to 30127
Control data
Axis 01
Axis 02
Axis 31
Axis 32
.
.
.
.
.
.
.
.
.
Status data
Содержание CS1W-MCH71 -
Страница 2: ...CS1W MCH71 CJ1W MCH71 Motion Control Unit Operation Manual Revised June 2008 ...
Страница 3: ...iv ...
Страница 29: ...xxx ...
Страница 33: ...xxxiv ...
Страница 35: ...xxxvi ...
Страница 39: ...xl ...
Страница 69: ...24 Performance Section 1 7 ...
Страница 99: ...54 Connecting MECHATROLINK Devices Section 3 5 ...
Страница 283: ...238 Saving Data Section 5 4 ...
Страница 417: ...372 Command Details Section 6 3 ...